{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2063-7KP36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2063-7KP36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2063-7KP36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2063-7KP36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2063-7KP36-0AA0, 3-pole molded case circuit breaker, 63 A continuous, ETU850 electronic overcurrent release, line protection design, 86 mm depth.","salesMarkdown":"It's a current-production part — still in active manufacture, so no last-time-buy scramble for BOM lines that specify it. That's unusual for a compact MCCB and simplifies panel thermal calculations. The ETU850 electronic trip unit offers an adjustable overload setting from 95 A minimum up to 756 A maximum (the frame's ultimate limit). That wide band lets you tune the breaker to the actual load without swapping hardware — useful when the same panel build serves different motor sizes. Short-circuit current ratings: 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 3 kA at 690 V. Mount it in a panel with at least IP54 overall if the environment sees washdown or condensation. Communication function is built in — the ETU850 supports data exchange with the SENTRON powermanagement system for load monitoring and selective coordination studies. No external module required for basic bus communication.","metaTitle":"Siemens 3VA2063-7KP36-0AA0 SENTRON MCCB, 63 A, ETU850, 3-Pol","metaDescription":"Siemens 3VA2063-7KP36-0AA0 SENTRON molded case circuit breaker, 63 A continuous, ETU850 electronic trip, 3-pole, 330 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"3 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 40% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"100 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0b471a051bb06580f1d41a3c25352a15.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=409087&mlfb=3VA2063-7KP36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2063-7KP36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2063-7KP36-0AA0 drop into a panel specified around 3VA2063-8JQ42-0AA0 without rewiring?","answer":"Both are 3-pole SENTRON MCCBs on the same 3VA frame, so the mounting footprint and bus-bar spacing are identical. The difference is in the trip unit — the 7KP36 uses an ETU850 electronic trip, while the 8JQ42 variant carries a different trip curve. Panel cutout and wiring positions are the same; no rewiring needed if the trip curve matches the load."},{"question":"What is the depth of 3VA2063-7KP36-0AA0?","answer":"86 mm (3.39 in). That's the dimension from the mounting surface to the front face — critical for shallow enclosure fit."},{"question":"What compliance documentation does this brand provide for 3VA2063-7KP36-0AA0?","answer":"As a Siemens SENTRON product, it carries the usual CE marking for European markets and UL/CSA listings for North American installations. RoHS and REACH declarations are standard with the product documentation package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2063-7KP36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2063-7KP36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}