{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-0HL36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-0HL36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-0HL36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-0HL36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-0HL36-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU320 electronic trip unit, line protection, 440 kA at 415 V AC, 690 V AC rated voltage, IP40 front.","salesMarkdown":"## What this MCCB is and what it does The Siemens 3VA2110-0HL36-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection — meaning it sits upstream protecting feeders and distribution from overcurrents and short circuits, not as a motor starter. It carries a continuous rated current of 100 A across the full ambient range from 40 °C to 70 °C (–), so you don't have to derate for higher panel temperatures. The ETU320 electronic trip unit gives you adjustable overload and short-circuit protection curves, which is handy when coordinating with downstream breakers in a selective system. ## Breaking capacity — the real-world number This breaker's interrupting rating is 440 kA at 415 V AC and 187 kA at 690 V AC. That 440 kA figure at 415 V is what you care about for most industrial low-voltage distribution — it means the breaker can safely clear a fault current up to that level without rupturing, which is important when it's installed near a large transformer or in a high-fault-current panel. The 690 V rating covers 600 V class systems common in North America and some European 690 V drives. ## Panel fit and mounting Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep (–). That width is standard for a 3-pole MCCB in the SENTRON 3VA frame — it fits the same mounting footprint as other 3VA breakers, so swapping in a panel that already has busbar cutouts or lug kits should be straightforward. The front face carries an IP40 protection class, meaning it's protected against tools and small wires but not sealed against water — fine for indoor panel mounting.","metaTitle":"Siemens 3VA2110-0HL36-0AA0 SENTRON MCCB, 100 A, 3-Pole, 440","metaDescription":"Siemens 3VA2110-0HL36-0AA0 SENTRON molded case circuit breaker, 100 A rated, 3-pole, 440 kA breaking capacity at 415 V. ETU320 release. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"0 A","Minimum":"0 A","at 415 V":"440 kA","at 690 V":"187 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1417386&mlfb=3VA2110-0HL36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-0HL36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2110-0HL36-0AA0?","answer":"It has a breaking capacity of 440 kA at 415 V AC and 187 kA at 690 V AC. The 440 kA figure is the one to check for typical 400 V distribution panels."},{"question":"How do I get current pricing and availability for 3VA2110-0HL36-0AA0?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-0HL36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-0HL36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}