{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-0HM36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-0HM36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-0HM36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-0HM36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-0HM36-0AA0, molded case circuit breaker, 3-pole, 100 A continuous, ETU330 electronic trip unit, line protection design.","salesMarkdown":"The Siemens SENTRON 3VA2110-0HM36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current, using an ETU330 electronic trip unit for line protection. It's designed to sit on a DIN rail inside a distribution or motor control center panel, where the 86 mm depth and 105 mm width keep the footprint compact for a 100 A frame. At 415 V this MCCB interrupts up to 440 kA, and at 690 V it still handles 187 kA. That SCCR gives you real selectivity headroom downstream — you can coordinate with smaller branch breakers without worrying about cascading failure on a high-fault transformer or large motor start. ## Thermal stability across the panel ambient range The 100 A rating holds flat from 40 °C all the way to 70 °C — no derating needed inside a warm enclosure. That's unusual for an MCCB; most require a knock-down above 40 °C. Operating ambient from -25 °C to 70 °C, with storage from -40 °C to 80 °C. Power dissipation at rated current is 7.7 W, manageable for thermal calculations in a sealed panel. ## Front IP40 and compliance Rated insulation voltage is 800 V, so it's comfortable on 480 V and 600 V class systems with margin.","metaTitle":"Siemens 3VA2110-0HM36-0AA0 SENTRON MCCB, 100A, 3-Pole, ETU33","metaDescription":"Siemens 3VA2110-0HM36-0AA0 SENTRON molded case circuit breaker, 100A continuous, 3-pole, ETU330 release. 440 kA at 415 V. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 415 V":"440 kA","at 690 V":"187 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"20 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Full-Scale Value":"100 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU330","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1417390&mlfb=3VA2110-0HM36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-0HM36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-0HM36-0AA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2110-0HM36-0AA0's listed depth?","answer":"The depth is 86 mm (3.39 in). Width is 105 mm (4.13 in), height is 181 mm (7.13 in)."},{"question":"Will 3VA2110-0HM36-0AA0 drop into a panel specified around 3VA2116-5JP32-0AE0 without rewiring?","answer":"Both are 3-pole SENTRON MCCBs on the same 3VA frame, so the mounting footprint and bus-bar centers are identical. The difference is in the trip unit and rating — the 3VA2116-5JP32-0AE0 carries a higher continuous current and different electronic trip. If your panel is wired and bused for the 3VA2116 frame, this 3VA2110-0HM36-0AA0 will physically fit, but verify the load current and protection settings match your circuit before swapping."},{"question":"What compliance documentation does Siemens provide for 3VA2110-0HM36-0AA0?","answer":"Siemens SENTRON 3VA series MCCBs carry UL, CSA, IEC, and CE certifications as standard. RoHS and REACH declarations are included with the product documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-0HM36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-0HM36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}