{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL32-0AH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL32-0AH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0AH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL32-0AH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL32-0AH0, molded case circuit breaker, 3-pole, 100 A, ETU320 electronic trip unit, line protection, breaking capacity 187 kA at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA2110-5HL32-0AH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current (Iu) with an ETU320 electronic trip unit, configured for line protection. Its interrupting capacity hits 187 kA at 240 V and 121 kA at 415 V, which means it can clear high-fault currents without cascading upstream — a key spec for main or feeder breakers in industrial switchboards where SCCR headroom matters. The ETU320 trip unit provides adjustable thermal-magnetic or electronic protection curves (L, S, I, G depending on configuration), though this variant ships without ground-fault monitoring or communication functions. The 100 A rating holds flat from 40 °C to 50 °C, then derates linearly to 85 A at 70 °C — useful to know when the breaker sits in a warm enclosure near other heat sources. Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits most Siemens SENTRON mounting bases and busbar systems.","metaTitle":"Siemens 3VA2110-5HL32-0AH0 MCCB, 100 A, 3-Pole, ETU320, 187","metaDescription":"Siemens SENTRON 3VA2110-5HL32-0AH0 molded case circuit breaker, 100 A rated continuous current, 3-pole, ETU320 electronic trip unit, breaking capacity 187 kA at 240 V. Current prod","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2110-5HL32-0AH0","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit 2 auxiliary switches HQ 1 trip alarm switch HQ","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5HL32-0AA0","Design of the auxiliary release":"Without auxiliary release","Ground fault monitoring version":"Without","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=226883&mlfb=3VA2110-5HL32-0AH0"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-5HL32-0AH0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"Will 3VA2110-5HL32-0AH0 drop into a panel specified around 3VA1110-5EE32-0JA0 without rewiring?","answer":"The 3VA2110-5HL32-0AH0 shares the same 3-pole form factor and SENTRON mounting footprint as the 3VA1110 series, so it fits the same busbar and enclosure cutout. The key difference is the ETU320 electronic trip unit versus the thermal-magnetic release on the 3VA1110 — verify the protection curve and auxiliary contact wiring before swapping."},{"question":"What compliance documentation does this brand provide for 3VA2110-5HL32-0AH0?","answer":"Siemens SENTRON MCCBs are typically supplied with IEC 60947-2 certification, CE marking, and UKCA; RoHS and REACH declarations are available from the manufacturer. Specific document pack should be requested at order time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0AH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL32-0AH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}