{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL32-0BL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL32-0BL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0BL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL32-0BL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL32-0BL0, Molded case circuit breaker, 3-pole, 100 A, line protection, ETU320, breaking capacity 187 kA at 240 V.","salesMarkdown":"## Siemens SENTRON 3VA2110-5HL32-0BL0 — 100 A MCCB, Line Protection, ETU320 It carries a rated insulation voltage Ui of 800 V and delivers a breaking capacity of 187 kA at 240 V, 121 kA at 415 V, 121 kA at 440 V, 79 kA at 500 V, and 4.25 kA at 690 V — the high 187 kA at 240 V makes it suitable for high-fault utility or transformer secondary applications where fault currents can exceed 100 kA. Above 50 °C it derates: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. For a panel that runs warm — say 55 °C inside a NEMA 12 enclosure — the breaker is good for 96.25 A continuous without nuisance tripping. ## Release, auxiliaries, and accessories Overcurrent protection is handled by the ETU320 electronic trip unit — a basic fixed-time curve with no communication or ground-fault monitoring. A mechanical trip indicator is present. Maximum power loss is 12.5 W.","metaTitle":"Siemens 3VA2110-5HL32-0BL0 SENTRON MCCB, 100 A, 3-pole, Line","metaDescription":"Siemens SENTRON 3VA2110-5HL32-0BL0 molded case circuit breaker, 100 A rated continuous current Iu, 3-pole, ETU320 release, line protection. Breaking capacity at 240 V: 187 kA. Acti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2110-5HL32-0BL0","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"12.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=60118&mlfb=3VA2110-5HL32-0BL0"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5HL32-0BL0 and how do I get a price?","answer":"The part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"Will 3VA2110-5HL32-0BL0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?","answer":"The physical dimensions are identical, so it fits the same DIN-rail footprint and busbar spacing. However, the 3VA2110-5HL32-0BL0 includes an undervoltage release that requires a separate control-circuit connection; the 3VA1010-2ED32-0JA0 does not have this release. If the original panel had no UVR wiring, adding the 3VA2110-5HL32-0BL0 means pulling a control wire for the UVR coil."},{"question":"What compliance documentation does Siemens provide for this breaker?","answer":"The evidence does not list specific compliance certificates. For a BOM requiring RoHS, REACH, UL, or IEC declarations, request the manufacturer's compliance documentation at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0BL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL32-0BL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}