{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL32-0CH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL32-0CH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0CH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL32-0CH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL32-0CH0, molded case circuit breaker, 3-pole, 100 A continuous, line protection, breaking capacity 187 kA at 240 V.","salesMarkdown":"It carries a maximum breaking capacity of 187 kA at 240 V AC, tapering to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the high interrupt rating at the lower voltages makes it a strong fit for fault-current-heavy service-entrance or main feeder positions where available fault current is high. A mechanical trip indicator is present on the front face for quick visual fault identification during walk-throughs. ## Thermal performance and panel fit Maximum power loss is 12.5 W, which is manageable for a DIN-rail or backplate layout but should be factored into the enclosure heat budget if the panel packs multiple breakers side by side. Dimensions are 181 mm high, 105 mm wide, and 86 mm deep (7.13 x 4.13 x 3.39 inches).","metaTitle":"Siemens SENTRON 3VA2110-5HL32-0CH0 MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2110-5HL32-0CH0 molded case circuit breaker, 100 A continuous, 3-pole, line protection, breaking capacity 187 kA at 240 V. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=16868&mlfb=3VA2110-5HL32-0CH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL32-0CH0/alternatives.json"},"ai":{"faq":[{"question":"Does this breaker include auxiliary contacts or an undervoltage release?","answer":"Yes, it ships with two auxiliary switches plus one trip alarm switch (HQ configuration) and an integrated undervoltage release. A mechanical trip indicator is also fitted on the front."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0CH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL32-0CH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}