{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL32-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL32-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL32-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL32-0HH0, molded case circuit breaker, 3-pole, 100 A continuous, adjustable thermal-magnetic trip 150-1200 A, 187 kA at 240 V, line protection design, shunt trip release, 2 aux + 1 alarm switch.","salesMarkdown":"The Siemens SENTRON 3VA2110-5HL32-0HH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, with an adjustable thermal-magnetic trip unit covering 150 A to 1,200 A. That trip range means you can set it for a feeder or a large motor branch without swapping the breaker body — useful when the load calc lands somewhere between 150 A and the full 1,200 A ceiling. The interrupting ratings climb to 187 kA at 240 V and hold at 121 kA through 440 V, then taper to 75.6 kA at 500 V and 3.7 kA at 690 V. Power loss maxes at 10 W, so it won't cook the panel. The 3-pole footprint is standard for a 100 A frame; you'll need about 4 inches of rail width per breaker. The shunt trip and aux switches are factory-installed, so no field wiring of add-on modules.","metaTitle":"Siemens 3VA2110-5HL32-0HH0 SENTRON MCCB, 100 A, 150-1200 A t","metaDescription":"Siemens SENTRON 3VA2110-5HL32-0HH0 molded case circuit breaker, 100 A continuous, adjustable trip 150-1200 A, 187 kA at 240 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=13977&mlfb=3VA2110-5HL32-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL32-0HH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5HL32-0HH0 and how is it quoted?","answer":"We source and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network."},{"question":"What are the key ratings for 3VA2110-5HL32-0HH0?","answer":"100 A continuous, adjustable trip 150-1,200 A, 3-pole, interrupting capacity 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, 3.7 kA at 690 V. Includes shunt trip and 2 aux + 1 alarm switch."},{"question":"Will 3VA2110-5HL32-0HH0 drop into a panel specified around 3VA2116-5HL32-0AK0?","answer":"Both are SENTRON 3VA2 frame breakers with the same physical footprint (105 mm wide, 181 mm tall, 86 mm deep). The 3VA2110 is a 100 A continuous frame; the 3VA2116 is a 160 A frame. They share the same mounting hole pattern and DIN-rail clip spacing, so a swap is mechanically straightforward. The trip unit range differs — the 3VA2116 covers 160-1,200 A — so verify the trip setting matches your load before installing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL32-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL32-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}