{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL36-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL36-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL36-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL36-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL36-0BA0, molded case circuit breaker, line protection, 3-pole, 100 A rated continuous Iu, 187 kA breaking capacity at 240 V AC, ETU320 electronic trip unit, undervoltage release.","salesMarkdown":"## MCCB for high-fault panel feeds The 187 kA at 240 V is the headline number, but the real-world selectivity story is at 415 V and 440 V, where it still holds 121 kA — enough to coordinate with most downstream distribution breakers in a 400 V industrial panel. At 500 V the rating drops to 79 kA, and at 690 V it falls to 4.25 kA, so this frame is not intended for 690 V main feeds; that's a motor-circuit or sub-distribution role at the lower end of the voltage range. ## Thermal derating and panel fill The breaker holds 100 A from 40 °C through 50 °C, then derates linearly to 85 A at 70 °C.","metaTitle":"Siemens 3VA2110-5HL36-0BA0 SENTRON MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-5HL36-0BA0 molded case circuit breaker, 100 A rated continuous, 187 kA breaking at 240 V. ETU320 release, undervoltage release. Active production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"12.5 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5HL36-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=332046&mlfb=3VA2110-5HL36-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL36-0BA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2110-5HL36-0BA0 at 415 V?","answer":"121 kA at 415 V AC, which is the same rating as at 440 V. At 240 V it reaches 187 kA."},{"question":"Does 3VA2110-5HL36-0BA0 include an undervoltage release?","answer":"Yes, it is equipped with an undervoltage release (UVR) as the auxiliary release, factory-installed. The UVR trips the breaker when control voltage drops below a set threshold, enabling safety circuit integration without a separate shunt trip."},{"question":"Where can I buy 3VA2110-5HL36-0BA0 and what is the lead time?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — lead time and stock position are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL36-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL36-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}