{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL36-0DC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL36-0DC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL36-0DC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL36-0DC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL36-0DC0, 3-pole molded case circuit breaker, 100 A continuous rating, line protection design, 187 kA breaking capacity at 240 V, with undervoltage release and 2 auxiliary switches HQ.","salesMarkdown":"Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the steep drop above 500 V means this breaker is sized for low-voltage main or feeder duty, not 690 V branch circuits. The thermal-magnetic trip unit adjusts between 150 A and 1 200 A, so the 100 A frame carries headroom for coordination studies. ## Built-in undervoltage release and auxiliary switching Two HQ auxiliary switches are also integrated, giving the panel builder a Form-C feedback signal for the PLC or status lamp without adding a separate accessory block. ## Thermal performance across the panel ambient range Power dissipation maxes at 12.5 W, which is modest for a 100 A frame and won't drive a ventilation redesign in a typical IP54 cabinet.","metaTitle":"Siemens 3VA2110-5HL36-0DC0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2110-5HL36-0DC0 molded case circuit breaker, 100 A continuous, 3-pole, line protection with undervoltage release. Breaking capacity 187 kA at 240 V. Current prod","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=200303&mlfb=3VA2110-5HL36-0DC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL36-0DC0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for 3VA2110-5HL36-0DC0?","answer":"100 A continuous, 3-pole, breaking capacity 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 500 V, 3.7 kA at 690 V. Trip unit adjustable 150–1 200 A. Includes undervoltage release and two HQ auxiliary switches."},{"question":"Where can I buy 3VA2110-5HL36-0DC0?","answer":"This MCCB is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What is the difference between 3VA2110-5HL36-0DC0 and 3VA1110-5EE32-0LC0?","answer":"The 3VA1110-5EE32-0LC0 is a different SENTRON frame variant — the 3VA2110 carries the undervoltage release and auxiliary switches factory-fitted, while the 3VA1110 series typically omits those accessories. Panel cutout dimensions differ between the two frame sizes; verify the mounting footprint before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL36-0DC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL36-0DC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}