{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HL36-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HL36-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HL36-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL36-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HL36-0HH0, molded case circuit breaker, 3-pole, 100 A rated continuous current, ETU320 electronic trip unit, 187 kA interrupting at 240 V AC, shunt trip release, auxiliary switches + trip alarm.","salesMarkdown":"The Siemens SENTRON 3VA2110-5HL36-0HH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current at 40 °C, with an ETU320 electronic overcurrent release and an integrated shunt trip (STL). That is a practical detail for a panel builder who wants remote indication without adding a separate auxiliary block. Above that, the derating curve is published: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. That is the number to use for NEC ampacity calculations, not the und derated nameplate. ## Interrupting ratings across voltage classes The 187 kA at 240 V AC is the headline figure, but the more relevant number for a 480 V distribution panel is the 121 kA at 440 V. At 500 V it still holds 79 kA; at 690 V it drops to 4.25 kA. For a 400/415 V system with a transformer secondary capable of 100 kA, this breaker has the interrupting margin. Dimensions are 181 mm height, 105 mm width, 86 mm depth. The 86 mm depth includes the arc-chamber protrusion behind the mounting plane; verify clearance against the enclosure back wall, especially if a rear-mounted bus bar or cable duct is present. ## Integrated trip unit and release options The shunt trip (STL) allows remote tripping from an emergency-stop circuit or a supervisory system. The breaker also ships with a voltage trigger (undervoltage release is not fitted on this variant). The basic switch supplied is order code 3VA2110-5HL36-0AA0; the integrated auxiliary trip module is 3VA9688-0BL30. These are the service parts if the auxiliary contact block needs replacement. ## Environmental limits Maximum power dissipation is 10 W at rated current — a modest heat load for a ventilated enclosure, but worth accounting for in a sealed, high-density panel with multiple breakers.","metaTitle":"Siemens 3VA2110-5HL36-0HH0 SENTRON MCCB, 100A, 3-Pole, 187kA","metaDescription":"Siemens SENTRON 3VA2110-5HL36-0HH0 molded case circuit breaker, 100A rated continuous current, 3-pole, 187kA interrupting at 240V. ETU320 release, shunt trip. Current lifecycle sta","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5HL36-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=53691&mlfb=3VA2110-5HL36-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HL36-0HH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5HL36-0HH0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What is the interrupting rating of 3VA2110-5HL36-0HH0 at 240 V?","answer":"187 kA at 240 V AC. At 415 V and 440 V it is rated 121 kA; at 500 V it drops to 79 kA; at 690 V it is 4.25 kA."},{"question":"Does 3VA2110-5HL36-0HH0 include a shunt trip?","answer":"Yes, it is fitted with a shunt trip (STL) release for remote tripping. The overcurrent release is an ETU320 electronic unit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HL36-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HL36-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}