{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HN36-0DC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HN36-0DC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HN36-0DC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HN36-0DC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HN36-0DC0, molded case circuit breaker, 3-pole, 100 A rated continuous current, 187 kA at 240 V, ETU350 electronic trip unit, undervoltage release, 2 HQ auxiliary switches, 105 x 181 x 86 mm.","salesMarkdown":"Its 100 A continuous current (Iu) holds through 50 °C ambient; above that it derates to 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C — so if the panel runs hot, size the breaker for the actual load at your ambient, not the nameplate 100 A. The interrupting ratings climb with voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. The 3VA2110-5HN36-0DC0 measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard 3-pole MCCB footprint that drops into SENTRON panelboards or standalone DIN-rail adapters. The auxiliary trip coil (3VA9608-0BB25) is factory-installed; no field wiring of a separate shunt trip module needed. The undervoltage release is wired to a control circuit — it holds the breaker closed as long as voltage is present, and trips on dropout below the release threshold. The 3VA2 frame is the successor to the older 3VL series, with a slimmer profile and the ETU electronic trip family. If you're replacing a 3VL breaker in an existing panel, check the mounting footprint and bus-bar spacing — the 3VA2 uses the same 105 mm width but the depth and terminal layout differ.","metaTitle":"Siemens 3VA2110-5HN36-0DC0 SENTRON MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-5HN36-0DC0 molded case circuit breaker, 100 A rated, 187 kA interrupting at 240 V. Active production, sourced to order. ETU350 release, undervoltage trip.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"12.5 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5HN36-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"1 200 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=446189&mlfb=3VA2110-5HN36-0DC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HN36-0DC0/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3VA2110-5HN36-0DC0?","answer":"The 3VA2010-5HL36-0BE0 is a sibling in the same SENTRON 3VA2 family, but it carries a different electronic trip unit and auxiliary configuration. The 3VA2110-5HN36-0DC0 has the ETU350 release and an integrated undervoltage release; the 3VA2010-5HL36-0BE0 uses a different trip curve and lacks the UVR. They share the same frame size and 100 A rating, but the trip unit and auxiliaries are not drop-in interchangeable — verify the protection settings and control wiring before substituting."},{"question":"What are the key ratings for 3VA2110-5HN36-0DC0?","answer":"Rated continuous current 100 A, interrupting capacity 187 kA at 240 V, 121 kA at 415 V, 79 kA at 500 V, 4.25 kA at 690 V. Rated insulation voltage 800 V. ETU350 electronic trip unit with undervoltage release. Two HQ auxiliary switches. Dimensions 105 x 181 x 86 mm."},{"question":"How do I get pricing and availability for 3VA2110-5HN36-0DC0?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and lead time are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HN36-0DC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HN36-0DC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}