{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5HN36-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5HN36-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5HN36-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HN36-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5HN36-0HH0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, ETU350, line protection, 2 aux + 1 alarm.","salesMarkdown":"The Siemens SENTRON 3VA2110-5HN36-0HH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current (Iu) across a 40 °C to 50 °C ambient — it holds full rating up to 50 °C, then derates to 85 A at 70 °C. That 100 A frame makes it a fit for main feeder or large motor branch protection in a 400 V distribution panel. Breaking capacity is the headline here: 187 kA at 240 V, 121 kA at 415/440 V, dropping to 79 kA at 500 V and 4.25 kA at 690 V. The 690 V figure (4.25 kA) is the weak point; verify fault current at that voltage before specifying. The ETU350 electronic trip unit handles the overcurrent protection — adjustable thermal-magnetic or electronic curve depending on the variant. The 3VA2110-5HN36-0HH0 is the line-protection variant with shunt trip. If your panel was originally specified around a 3VA1110-5EE32-0JA0 (a different frame size and trip unit), the physical footprint and bus-bar centers differ — it will not drop in without re-termination and coordination review. Stick with this exact order code for a like-for-like swap. The 70 °C operating limit at 85 A derating covers most machine-room environments.","metaTitle":"Siemens 3VA2110-5HN36-0HH0 SENTRON MCCB, 100 A, 187 kA","metaDescription":"Siemens SENTRON 3VA2110-5HN36-0HH0 molded case circuit breaker, 100 A rated continuous current, 187 kA breaking at 240 V. Line protection with ETU350. Current lifecycle stage. Sour","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5HN36-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"1 200 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=409280&mlfb=3VA2110-5HN36-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5HN36-0HH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5HN36-0HH0 and get a price?","answer":"We source and quote this part to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network."},{"question":"What is the breaking capacity of 3VA2110-5HN36-0HH0 at 415 V?","answer":"121 kA at 415 V, matching the 440 V rating. At 240 V it reaches 187 kA; at 500 V it drops to 79 kA."},{"question":"Does the 3VA2110-5HN36-0HH0 include a shunt trip?","answer":"Yes, it has a shunt trip (STL) auxiliary release as standard, plus 2 auxiliary switches and 1 trip alarm contact (HQ configuration)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5HN36-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5HN36-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}