{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JP32-0BL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JP32-0BL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0BL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0BL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JP32-0BL0, molded case circuit breaker, 100 A, 3-pole, line protection, 187 kA interrupting at 240 V, with undervoltage release and communication function.","salesMarkdown":"The interrupting ratings climb steeply at lower voltages — 187 kA at 240 V — and stay strong at 415/440 V at 121 kA, then taper to 75.6 kA at 500 V and 3.7 kA at 690 V. The 100 A continuous rating at 70 °C is the number that matters for a warm panel — many MCCBs start derating above 40 °C, but this one holds 100 A all the way to 70 °C, so it's a solid pick for a crowded switchboard or a hot environment like a steel mill or foundry. For a 480 V distribution panel, the 121 kA at 440 V still gives serious headroom for a 100 A feeder. The unit includes a communication function, so it can talk to a higher-level system for monitoring or remote trip — useful for a BMS or SCADA integration where you want status without a separate auxiliary contact block. Dimensions are 86 mm deep, 105 mm wide, 181 mm tall — that's a standard 3-pole MCCB footprint for a 100 A frame, so it drops into most panelboards designed for SENTRON or similar form-factor breakers. The undervoltage release is built in (not a field-add kit), so if the control voltage drops, the breaker trips — good for safety circuits where a loss of control power should kill the load. If you need GF protection, look at the 3VA2... with ground-fault option.","metaTitle":"Siemens 3VA2110-5JP32-0BL0 SENTRON MCCB, 100 A, 3-pole, 187","metaDescription":"Siemens SENTRON 3VA2110-5JP32-0BL0 molded case circuit breaker, 100 A continuous, 3-pole, 187 kA interrupting at 240 V. Active lifecycle. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2110-5JP32-0BL0","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 24V DC 2 auxiliary switches HQ 1 trip alarm switch HQ 1 electrical alarm switch","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105JP320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB11","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=385183&mlfb=3VA2110-5JP32-0BL0"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5JP32-0BL0 and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the interrupting rating of 3VA2110-5JP32-0BL0 at 240 V?","answer":"The interrupting rating at 240 V is 187 kA — that's a very high capacity, suitable for service-entrance or high-fault applications."},{"question":"Will 3VA2110-5JP32-0BL0 drop into a panel designed for 3VA2116-5JP32-0AE0?","answer":"Both are 3-pole SENTRON MCCBs in the same physical frame — dimensions are identical at 86 mm deep, 105 mm wide, 181 mm tall — so it will physically fit and wire the same way. The difference is the rating: this one is 100 A continuous; the 3VA2116 is a higher-current variant."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"As a current-production SENTRON MCCB, it carries Siemens standard compliance — UL, IEC, CSA, CE, and RoHS/REACH declarations are available through the Siemens support portal or upon request with an RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0BL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JP32-0BL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}