{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JP32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JP32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2110-5JP32-0DA0, 3-pole, 100 A rated continuous current, line protection design with undervoltage release and communication function.","salesMarkdown":"The Siemens 3VA2110-5JP32-0DA0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. Its 3-pole design handles line protection duty, with a rated insulation voltage of 800 V and breaking capacities that scale with system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. ## Panel fit and thermal performance Dimensions are 86 mm deep, 105 mm wide, and 181 mm tall — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. Power loss is 12.5 W maximum, which is modest for a 100 A frame and keeps internal panel temperature rise manageable in a sealed enclosure. Operating temperature range is -25 °C to 70 °C, with storage from -40 °C to 80 °C. The continuous current rating holds flat at 100 A from 40 °C through 70 °C — no thermal derating curve to calculate for typical industrial panel environments.","metaTitle":"Siemens 3VA2110-5JP32-0DA0 SENTRON MCCB, 100 A, 3-Pole, 187","metaDescription":"Siemens 3VA2110-5JP32-0DA0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, 187 kA breaking capacity at 240 V. Line protection with undervoltage release and communica","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2110-5JP32-0DA0","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU550, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105JP320AA0","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=442007&mlfb=3VA2110-5JP32-0DA0"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2110-5JP32-0DA0 at different voltages?","answer":"Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The 187 kA rating at 240 V makes it suitable for high-fault-current distribution panels."},{"question":"Does 3VA2110-5JP32-0DA0 require derating at elevated ambient temperatures?","answer":"No derating is needed — the 100 A continuous current rating holds flat from 40 °C through 70 °C ambient, simplifying panel design in warm environments."},{"question":"Where can I buy 3VA2110-5JP32-0DA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JP32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}