{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JP32-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JP32-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JP32-0DH0, molded case circuit breaker, 3-pole, 100 A, line protection with communication function, undervoltage release, and auxiliary switches.","salesMarkdown":"The Siemens SENTRON 3VA2110-5JP32-0DH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full operating range from -25 °C to 70 °C — no derating needed up to the top end. It is designed specifically for line protection (cable and busbar feeder protection), not motor or generator duty. The interrupting ratings climb with system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The trip unit adjustable range spans 150 A to 1 200 A, so the 100 A frame supports a wide band of protection settings. A trip indicator is present on the front face for quick visual identification of a tripped breaker on a crowded panel. That saves adding a separate auxiliary contact block in many coordination schemes. ## Selectivity and coordination notes Because this is a line-protection MCCB with an adjustable trip unit (150–1 200 A range), it can be coordinated downstream of a larger SENTRON 3VA breaker or upstream of a 3VA1 frame. The 100 A continuous rating and 187 kA SCCR at 240 V give headroom for a high-fault panelboard. For a site engineer building a selective coordination study, the trip curve data (I²t and instantaneous settings) is available in the Siemens selectivity manual — not reproduced here, but the part is designed for full selectivity with downstream 3VA1 breakers up to the interrupting rating. The undervoltage release (UVR) also allows remote tripping from a safety PLC or E-stop circuit, which is useful for emergency-off zones.","metaTitle":"Siemens 3VA2110-5JP32-0DH0 SENTRON MCCB, 100 A, 3-Pole, Line","metaDescription":"Siemens 3VA2110-5JP32-0DH0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, line protection with communication function and undervoltage release. Active production, s","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105JP320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=530302&mlfb=3VA2110-5JP32-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0DH0/alternatives.json"},"ai":{"faq":[{"question":"Does 3VA2110-5JP32-0DH0 include an undervoltage release?","answer":"Yes, it is equipped with an undervoltage release (UVR) that trips the breaker when control voltage drops below a set threshold, suitable for emergency-stop or safety-shutdown circuits."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JP32-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}