{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JP32-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JP32-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JP32-0HC0, 3-pole molded case circuit breaker, 100 A continuous, 187 kA breaking at 240 V, line protection with shunt trip and communication.","salesMarkdown":"The Siemens SENTRON 3VA2110-5JP32-0HC0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the full ambient range from 40 °C through 70 °C — no derating needed up to that ceiling. Breaking capacity hits 187 kA at 240 V AC, 121 kA at 415 V and 440 V, then drops to 75.6 kA at 500 V and 3.7 kA at 690 V. That 187 kA figure at 240 V means it handles high-fault utility feeds or transformer secondaries where available short-circuit current is substantial; the 3.7 kA at 690 V still covers most industrial motor branch circuits at that voltage class. The 10 W maximum power loss is modest for a 100 A frame; panel ventilation is still advisable in a sealed enclosure. The 86 mm depth includes the body and the rotary handle; allow clearance for cable bending radius behind the panel, especially with the shunt trip wiring and communication connector. ## Breaking capacity by voltage — the so-what At 500 V the breaker still manages 75.6 kA, which covers most 480 V North American panelboards. The steep drop to 3.7 kA at 690 V means this frame is not the right choice for 690 V systems with high fault current; for those, step up to a higher-rated 3VA frame.","metaTitle":"Siemens SENTRON 3VA2110-5JP32-0HC0 MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-5JP32-0HC0 molded case circuit breaker, 3-pole, 100 A continuous, 187 kA breaking at 240 V. Line protection with shunt trip. Current lifecycle. Quoted to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105JP320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=486220&mlfb=3VA2110-5JP32-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0HC0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-5JP32-0HC0?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront; the part is sourced through independent distribution and quoted to order."},{"question":"What is the closest functional alternative to 3VA2110-5JP32-0HC0?","answer":"The 3VA2116-5JP32-0AE0 is a sibling in the same 3VA platform with a higher current rating. The 3VA2110-5JP32-0HC0 carries 100 A continuous; the 3VA2116-5JP32-0AE0 steps up to a higher frame rating. Both share the 3-pole form factor and shunt trip option, but the 0HC0 variant includes communication function while the 0AE0 may not — verify the specific order code's feature set before substituting."},{"question":"Will 3VA2110-5JP32-0HC0 drop into a panel specified for 3VA2116-5JP32-0AE0?","answer":"The physical footprint is identical — same 105 mm width, same 181 mm height, same 86 mm depth. Both are 3-pole SENTRON 3VA breakers. The 0HC0 variant includes a communication function and shunt trip; the 0AE0 variant may have different auxiliary configuration. Mounting holes and bus-bar spacing are shared across the frame size, so mechanical fit is the same. Electrical ratings differ — verify the 100 A continuous rating of the 0HC0 against the 0AE0's rating before swapping."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"As a Siemens SENTRON product, this MCCB carries CE marking for the European market and is designed to meet IEC 60947-2. UL and CSA listings are typical for the 3VA platform, but specific certification for this order code should be verified against the manufacturer's declaration. RoHS and REACH compliance documentation is available from Siemens upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JP32-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-14T23:37:48.546Z","lastPublished":"2026-09-14T23:37:48.546Z","indexable":true}}