{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JP32-0KC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JP32-0KC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0KC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0KC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JP32-0KC0, molded case circuit breaker, 3-pole, 100 A rated, 187 kA at 240 V, ETU550 trip unit, shunt trip, 2 auxiliary switches HQ.","salesMarkdown":"The Siemens SENTRON 3VA2110-5JP32-0KC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 100 A continuously at 40 °C and interrupting up to 187 kA at 240 V. At 55 °C it drops to 96.25 A, at 60 °C to 92.5 A, and at 70 °C to 85 A. The interrupting curve falls off with voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. The shunt trip (STL) is built in — part number 3VA9688-0BL33 for the integrated auxiliary trip. Two auxiliary switches (HQ type) are included, giving you status feedback for the PLC or a remote annunciator. Communication function is present — the ETU550 supports it via a plug-in module. ## Panel fit That 105 mm width is a standard 4-module (4 x 27 mm) footprint for SENTRON 3VA2 breakers — it clips onto the mounting plate or DIN rail adapter. The 86 mm depth includes the handle and terminals; leave clearance for cable bending radius below the line and load lugs.","metaTitle":"Siemens 3VA2110-5JP32-0KC0 SENTRON MCCB, 100A, 187kA at 240V","metaDescription":"Siemens SENTRON 3VA2110-5JP32-0KC0 molded case circuit breaker, 100A rated, 187kA interrupting at 240V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5JP32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU550","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"60 A","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=155039&mlfb=3VA2110-5JP32-0KC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP32-0KC0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of this MCCB at 240 V?","answer":"187 kA at 240 V, which is the highest interrupting rating on this breaker — suitable for high-fault-capacity transformer secondaries."},{"question":"What is the closest functional alternative to 3VA2110-5JP32-0KC0?","answer":"The 3VA1110-5EE32-0JA0 is a simpler fixed-thermal version without the ETU550 electronic trip unit. It drops into the same panel footprint but lacks adjustable protection curves and communication. Choose the 3VA2110 if you need the electronic trip; the 3VA1110 for a cost-sensitive fixed-thermal application."},{"question":"Where can I buy 3VA2110-5JP32-0KC0 and how is it quoted?","answer":"This part is sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"Does this breaker include a shunt trip?","answer":"Yes, the design includes a shunt trip release (STL). The integrated auxiliary trip module is order code 3VA9688-0BL33."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JP32-0KC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JP32-0KC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}