{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JP42-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JP42-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JP42-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP42-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JP42-0AA0, molded case circuit breaker, 4-pole, 100 A, ETU550 electronic trip unit, line protection version, communication capable.","salesMarkdown":"## 100 A, flat across the thermal curve — no derate to 70 °C That means no thermal derating for a warm panel — the full 100 A is available at 70 °C ambient, not a short-time or special-condition rating. The ETU550 electronic trip unit handles the overcurrent protection logic. Breaking capacity runs 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. At 690 V the available fault current drops sharply, so confirm the system's prospective short-circuit current at that voltage level before specifying. Four poles, communication function onboard, and an optional motor drive — this is a line-protection MCCB that fits a distribution or motor control center with a 400 V to 690 V supply. The 140 mm width and 86 mm depth place it in the standard SENTRON 3VA mounting footprint; no special adapter plate needed for a panel designed around the 3VA family. The 86 mm depth and 140 mm width keep it within the DIN-rail or mounting-plate envelope typical of a 4-pole MCCB in a 600 mm wide distribution board. Spring-cage terminals (standard for the 3VA family) accept copper conductors up to the rated cross-section; no lug kit required unless the installer prefers ring terminals.","metaTitle":"Siemens 3VA2110-5JP42-0AA0 SENTRON MCCB, 100 A, 4-Pole, ETU5","metaDescription":"Siemens SENTRON 3VA2110-5JP42-0AA0 molded case circuit breaker, 100 A continuous at 70 °C, 4-pole, ETU550 electronic trip. 187 kA at 240 V. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=507523&mlfb=3VA2110-5JP42-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JP42-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-5JP42-0AA0?","answer":"Submit an RFQ through the storefront; pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is 3VA2110-5JP42-0AA0's listed depth and width?","answer":"Depth is 86 mm, width is 140 mm."},{"question":"Will 3VA2110-5JP42-0AA0 drop into a panel designed for 3VA1110-5EF32-0LA0?","answer":"Both are SENTRON 3VA-series MCCBs sharing the same mounting footprint, so the 3VA2110-5JP42-0AA0 fits the same panel cutout and DIN-rail spacing. Verify the terminal arrangement and auxiliary contact positions against the existing wiring plan."},{"question":"What compliance documentation is available for 3VA2110-5JP42-0AA0?","answer":"The SENTRON series carries IEC 60947-2 certification. Specific RoHS, REACH, UL, and CSA declarations are available from the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JP42-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JP42-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}