{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JQ32-0AD0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JQ32-0AD0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JQ32-0AD0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JQ32-0AD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JQ32-0AD0, molded case circuit breaker, 3-pole, 100 A, ETU560 electronic trip unit, line protection, 187 kA at 240 V.","salesMarkdown":"For a packaging line running multiple motor starters and heater loads off one feeder, the ETU560 lets you coordinate selectively with downstream breakers so a single fault doesn't drop the whole machine. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. At 415 V — common for European three-phase distribution — 121 kA covers most industrial transformer ratings without needing a current-limiting upstream fuse. If your panel sits near ovens or in a non-conditioned enclosure, that derating curve tells you the real ampacity without guessing. ## Trip unit and protection logic That saves panel space and wiring compared to add-on ground-fault modules. For a line that tracks uptime and fault events, this avoids a separate monitoring relay. Three auxiliary switches (HQ type) are integrated for remote status indication — open/closed, tripped, and ground-fault alarm. No separate auxiliary contact block needed. Keep it inside a locked panel, not on the machine surface.","metaTitle":"Siemens 3VA2110-5JQ32-0AD0 SENTRON MCCB, 100 A, 3-pole, ETU5","metaDescription":"Siemens 3VA2110-5JQ32-0AD0 SENTRON molded case circuit breaker, 100 A rated, 3-pole, ETU560 trip unit, 187 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2110-5JQ32-0AD0","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU560, LSIG, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit 3 auxiliary switches HQ","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","Auxiliary contact version":"3 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5JQ32-0AA0","Design of the auxiliary release":"Without auxiliary release","Ground fault monitoring version":"Summation current formation L-conductor","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / lg max.":"100 A","Adjustable response value current / lg min.":"20 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"60 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LSIG","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=234813&mlfb=3VA2110-5JQ32-0AD0"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2110-5JQ32-0AD0 at 415 V?","answer":"121 kA at 415 V, which is the same rating as at 440 V. At 240 V it reaches 187 kA."},{"question":"Does 3VA2110-5JQ32-0AD0 include ground-fault protection?","answer":"Yes, the ETU560 trip unit provides ground-fault monitoring via summation current formation on the L-conductor, no external CT required."},{"question":"Where can I buy 3VA2110-5JQ32-0AD0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JQ32-0AD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JQ32-0AD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}