{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5JQ32-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5JQ32-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5JQ32-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JQ32-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5JQ32-0HC0, molded case circuit breaker, 3-pole, 100 A, adjustable thermal-magnetic trip 20-100 A, line protection, with shunt trip and 2 auxiliary switches HQ.","salesMarkdown":"The Siemens 3VA2110-5JQ32-0HC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous at 40 °C, with an adjustable thermal-magnetic trip unit covering 20 A to 100 A full-scale. Dimensions are 181 mm high, 105 mm wide, 86 mm deep — a standard 3-pole MCCB footprint for a SENTRON 3VA frame. The shunt trip (STL) and two auxiliary switches (HQ) are factory-fitted, so you don't lose a slot in the panel for add-on modules. Power loss is max 10 W, negligible for enclosure heat rise.","metaTitle":"Siemens 3VA2110-5JQ32-0HC0 SENTRON MCCB, 100 A, 3-Pole","metaDescription":"Siemens 3VA2110-5JQ32-0HC0 SENTRON molded case circuit breaker. 100 A continuous, adjustable trip 20-100 A. 187 kA at 240 V. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"20 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Full-Scale Value":"100 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105JQ320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU560","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=313511&mlfb=3VA2110-5JQ32-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5JQ32-0HC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5JQ32-0HC0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is 3VA2110-5JQ32-0HC0's listed depth?","answer":"The depth is 86 mm (3.39 in), which fits standard panel depths for 3VA frame MCCBs."},{"question":"What compliance documentation does this brand provide for 3VA2110-5JQ32-0HC0?","answer":"As a Siemens SENTRON product, it carries the usual CE, UL, CSA, and IEC certifications for molded case circuit breakers. Specific declarations (RoHS, REACH) are available on request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5JQ32-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5JQ32-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}