{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5KP32-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5KP32-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5KP32-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5KP32-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3VA2110-5KP32-0DH0, 3-pole, 100 A continuous, adjustable thermal-magnetic trip 150–1200 A, 187 kA interrupting at 240 V, line protection with communication function.","salesMarkdown":"Its adjustable thermal-magnetic trip unit covers 150 A to 1 200 A, so you set the pickup to match the downstream load rather than swapping the breaker. The interrupting ratings climb to 187 kA at 240 V and hold 121 kA at 415 V and 440 V, dropping to 75.6 kA at 500 V and 3.7 kA at 690 V — that SCCR headroom covers most industrial distribution panels without a current-limiting fuse upstream. This is a line-protection design with an undervoltage release and a built-in communication function for remote monitoring or trip indication. ## Thermal performance and power loss Maximum power loss is 12.5 W at rated current — modest enough that ventilation slots in a standard IP54 enclosure handle the heat without forced air.","metaTitle":"Siemens 3VA2110-5KP32-0DH0 SENTRON MCCB, 100 A, 3-Pole, 150-","metaDescription":"Siemens 3VA2110-5KP32-0DH0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole, adjustable trip 150-1200 A, 187 kA at 240 V. Active production. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Of The Supplied Basic Switch":"3VA21105KP320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=74210&mlfb=3VA2110-5KP32-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5KP32-0DH0/alternatives.json"},"ai":{"faq":[{"question":"What is the trip range on this MCCB?","answer":"The adjustable thermal-magnetic trip unit covers 150 A minimum to 1 200 A maximum. The breaker itself is rated for 100 A continuous."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5KP32-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5KP32-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}