{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5MN32-0DH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5MN32-0DH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5MN32-0DH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN32-0DH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5MN32-0DH0, molded case circuit breaker, 3-pole, 100 A, motor protection, ETU350M electronic trip unit, 187 kA at 240 V.","salesMarkdown":"## MCCB for motor protection — 100 A, ETU350M trip unit The Siemens 3VA2110-5MN32-0DH0 is a SENTRON molded case circuit breaker (MCCB) rated for motor protection duty, carrying a continuous current Iu of 100 A across the 40 °C to 50 °C band before derating begins at 55 °C. Breaking capacity reaches 187 kA at 240 V and 121 kA at 415/440 V, dropping to 75.6 kA at 500 V and 17 kA at 690 V. The 690 V rating of 17 kA is the limiting case — verify SCCR against the available fault current on that voltage class. The UVR drops the breaker on loss of control voltage — standard for safety circuits where a downstream E-stop or undervoltage condition must open the main power path. The 105 mm width matches the typical 3-pole SENTRON 3VA frame, so a panel laid out for a 3VA1110 or 3VA2010 will accept this unit without re-drilling the mounting holes.","metaTitle":"Siemens 3VA2110-5MN32-0DH0 SENTRON MCCB, 100 A, Motor Protec","metaDescription":"Siemens 3VA2110-5MN32-0DH0 SENTRON molded case circuit breaker, 100 A rated current, motor protection, ETU350M trip unit, 3-pole, 187 kA at 240 V. Active production. Quoted to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Motor protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"75 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-5MN32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU350M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 400 V":"45 W","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"4","Adjustable response value time / tsd max.":"0.03 s","Adjustable response value time / tsd min.":"0.03 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 500 A","Adjustable response value current / li min.":"1 500 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 500 A","Adjustable response value current / Isd min.":"300 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569353&mlfb=3VA2110-5MN32-0DH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN32-0DH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5MN32-0DH0 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time figure is published here."},{"question":"What is the breaking capacity of 3VA2110-5MN32-0DH0 at 415 V?","answer":"121 kA at 415 V, which is the same rating as at 440 V. At 240 V it reaches 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 17 kA."},{"question":"Does 3VA2110-5MN32-0DH0 include phase failure detection?","answer":"Yes, phase failure detection is built into the ETU350M trip unit, so a lost phase on the line side will trip the breaker to protect the motor."},{"question":"What auxiliary contacts are fitted on 3VA2110-5MN32-0DH0?","answer":"The breaker ships with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration), and an undervoltage release (UVR) as the auxiliary release design."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5MN32-0DH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5MN32-0DH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}