{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5MN32-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5MN32-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5MN32-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN32-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5MN32-0HC0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, motor protection design, shunt trip release, current production.","salesMarkdown":"## What this MCCB brings to a motor branch Rated 100 A continuously across the full ambient range from 40 °C to 70 °C — no derating curve to chase — and it delivers 187 kA interrupting capacity at 240 V, 121 kA at 415/440 V, and still holds 75.6 kA at 500 V. The 86 mm depth fits standard MCCB panel footprints — no deep-can requirement — and the 105 mm width means it occupies three pole spaces on a DIN-rail or panel-mount backplate. Maximum power loss is 10 W, so heat dissipation inside a sealed enclosure is manageable — no forced cooling needed for a single unit, but stack several in a row and the cumulative loss matters. ## Trip unit and release configuration No trip indicator on the front face — the auxiliary switches (2 HQ) provide remote status instead. Short-time delay is adjustable from 4 s minimum to 17 s maximum, which gives selectivity coordination room downstream.","metaTitle":"Siemens 3VA2110-5MN32-0HC0 SENTRON MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-5MN32-0HC0 molded case circuit breaker, 100 A rated current, 187 kA breaking capacity at 240 V. Motor protection design with shunt trip. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105MN320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"30 000 W","operating power / at AC-3 / at 400 V":"55 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569356&mlfb=3VA2110-5MN32-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN32-0HC0/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA2110-5MN32-0HC0's listed depth and width?","answer":"The depth is 86 mm and the width is 105 mm, fitting standard MCCB panel footprints."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5MN32-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5MN32-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}