{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5MN36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5MN36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5MN36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA2110-5MN36-0AA0, 3-pole, 100 A rated continuous current, motor protection design, adjustable trip class 10A/10E/20E.","salesMarkdown":"The Siemens 3VA2110-5MN36-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed specifically for motor protection, with a rated continuous current of 100 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling. Its 3-pole construction and motor protection design mean it's built for three-phase motor branch circuits, with phase failure detection built in and an adjustable trip class that lets you match the overload curve to the motor's thermal withstand: selectable between 10A, 10E, and 20E classes. The interrupting ratings span the voltage range you'd expect in industrial distribution: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The rated insulation voltage of 800 V gives headroom for 690 V systems, and the maximum power loss of 10 W is modest for a 100 A frame — panel thermal rise stays manageable even in a crowded enclosure. Dimensions are 105 mm wide by 181 mm high by 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without surprises. Operating temperature range is -25 °C to 70 °C, with storage from -40 °C to 80 °C, so it's suitable for unconditioned electrical rooms and outdoor-rated cabinets within those limits.","metaTitle":"Siemens 3VA2110-5MN36-0AA0 SENTRON MCCB, 100 A, 3-Pole, Moto","metaDescription":"Siemens 3VA2110-5MN36-0AA0 SENTRON molded case circuit breaker, 100 A continuous, 3-pole motor protection with adjustable trip class 10A/10E/20E. Breaking capacity 187 kA at 240 V.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"30 000 W","operating power / at AC-3 / at 400 V":"55 000 W","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$246.38","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569367&mlfb=3VA2110-5MN36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-5MN36-0AA0?","answer":"Pricing and availability are confirmed at quote time against an RFQ through our independent distribution channel — submit a request and we'll source it to order."},{"question":"What is the breaking capacity of this MCCB at 415 V?","answer":"121 kA at 415 V, which is the same rating as at 440 V — sufficient for high-fault industrial panels at that voltage level."},{"question":"Does this breaker include phase failure protection?","answer":"Yes, phase failure detection is built into the design, which is standard for motor protection MCCBs to prevent single-phasing damage."},{"question":"What trip classes are available on this unit?","answer":"The adjustable trip class can be set to 10A, 10E, or 20E, letting you match the overload curve to the motor's thermal withstand and starting characteristics."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5MN36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5MN36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}