{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5MN36-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5MN36-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5MN36-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN36-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5MN36-0CL0, molded case circuit breaker, 3-pole, 100 A, motor protection design, undervoltage release, 187 kA at 240 V.","salesMarkdown":"The Siemens 3VA2110-5MN36-0CL0 is a SENTRON molded case circuit breaker (MCCB) built for motor protection — 100 A continuous, 3-pole, with an undervoltage release integrated. It's the kind of breaker you spec into a motor branch circuit when you need thermal-magnetic protection plus a UVR for coordinated shutdown. Rated 187 kA at 240 V and 121 kA at 415 V, so it handles high-fault-current panels without cascading upstream. The 100 A rating holds flat from 40 °C to 70 °C — no derating curve to chase in a warm enclosure. Breaking capacity steps down with voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. That 3.7 kA at 690 V is the weak point; if your system runs 690 V with a high available fault current, this breaker won't clear it. Footprint is 105 mm wide, 181 mm tall, 86 mm deep — standard SENTRON 3VA2 frame size. The auxiliary switch block comes configured as 2 aux + 1 trip alarm + 1 electrical alarm (HQ), so you get status feedback without adding a separate module. Undervoltage release (UVR) is factory-fitted; verify coil voltage against your control circuit before wiring.","metaTitle":"Siemens 3VA2110-5MN36-0CL0 SENTRON MCCB, 100 A, 3-Pole, Moto","metaDescription":"Siemens 3VA2110-5MN36-0CL0 SENTRON molded case circuit breaker, 100 A rated, 3-pole, motor protection design, 187 kA at 240 V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105MN360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"30 000 W","operating power / at AC-3 / at 400 V":"55 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569383&mlfb=3VA2110-5MN36-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN36-0CL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5MN36-0CL0 and how do I get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"Will 3VA2110-5MN36-0CL0 drop into a panel that was specified around 3VA2116-5HL32-0AK0 without rewiring?","answer":"The 3VA2110-5MN36-0CL0 shares the same SENTRON 3VA2 frame dimensions (105 mm wide, 181 mm tall, 86 mm deep) as the 3VA2116-5HL32-0AK0, so it fits the same panel cutout and DIN-rail mounting. However, the 3VA2116 is a higher-current variant (160 A class); verify that the 100 A rating of the 3VA2110 meets your load requirements before swapping."},{"question":"What compliance documentation does this brand provide for 3VA2110-5MN36-0CL0?","answer":"Siemens SENTRON MCCBs typically carry UL, CSA, CE, and IEC certifications, plus RoHS and REACH declarations. Specific documentation for this order code is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5MN36-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5MN36-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}