{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-5MN36-0DC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-5MN36-0DC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-5MN36-0DC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN36-0DC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-5MN36-0DC0, molded case circuit breaker, 3-pole, 100 A, motor protection design, 187 kA breaking capacity at 240 V, with undervoltage release and phase failure detection.","salesMarkdown":"The Siemens SENTRON 3VA2110-5MN36-0DC0 is a 3-pole molded case circuit breaker (MCCB) rated at 100 A continuously across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. This MCCB carries a 187 kA interrupting rating at 240 V AC, dropping to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 3.7 kA at 690 V. For a motor feeder on a 415 V system with a prospective short-circuit current of, say, 85 kA, this breaker has headroom to spare. The 690 V figure (3.7 kA) is low enough that you should verify the available fault current if the breaker is applied on a 690 V line. The breaker ships with two auxiliary switches (HQ design) and the undervoltage release pre-installed; no separate add-on modules to order. ## Environmental range and storage The storage limits govern handling and warehousing, not running conditions. No ground-fault monitoring version is included (this unit is the standard motor-protection variant without GF).","metaTitle":"Siemens 3VA2110-5MN36-0DC0 SENTRON MCCB, 100 A, 3-Pole, Moto","metaDescription":"Siemens SENTRON 3VA2110-5MN36-0DC0 molded case circuit breaker, 100 A rated current, 3-pole, motor protection design with phase failure detection and undervoltage release. Breaking","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21105MN360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"30 000 W","operating power / at AC-3 / at 400 V":"55 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569385&mlfb=3VA2110-5MN36-0DC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-5MN36-0DC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-5MN36-0DC0 and how do I get a price?","answer":"We source and quote this part to order through our independent distribution channel. Submit an RFQ; availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2110-5MN36-0DC0's listed depth?","answer":"Depth is 86 mm (3.39 in)."},{"question":"What is 3VA2110-5MN36-0DC0's listed width?","answer":"Width is 105 mm (4.13 in)."},{"question":"What compliance documentation does this brand provide for 3VA2110-5MN36-0DC0?","answer":"As a Siemens SENTRON product, this MCCB is designed to meet IEC/EN 60947-2 and UL 489 standards. RoHS and REACH compliance documentation is available from Siemens upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-5MN36-0DC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-5MN36-0DC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}