{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HL32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HL32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HL32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HL32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2110-6HL32-0AA0, 100 A, 3-pole, ETU320 electronic trip unit, 242 kA breaking capacity at 240 V AC.","salesMarkdown":"The 3VA2110-6HL32-0AA0 is a SENTRON 3VA2 molded case circuit breaker rated for line protection, carrying 100 A continuously from 40 °C all the way up to 70 °C — no derating needed in a warm enclosure (–). That 100 A figure is the Iu, the uninterrupted current it can pass without tripping. Three poles, so it switches all phases on a three-phase feeder. Operating voltage rated up to 690 V AC. ## Breaking capacity — what it handles at fault The interrupting rating is where this breaker earns its keep: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. Power loss max 10 W — negligible for enclosure thermal budgeting.","metaTitle":"Siemens 3VA2110-6HL32-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3","metaDescription":"Siemens 3VA2110-6HL32-0AA0 SENTRON molded case circuit breaker, 100 A rated current, 3-pole, ETU320 release, 242 kA at 240 V. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Switching Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=118425&mlfb=3VA2110-6HL32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HL32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-6HL32-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"What is the breaking capacity of 3VA2110-6HL32-0AA0 at 240 V?","answer":"242 kA at 240 V AC."},{"question":"Will 3VA2110-6HL32-0AA0 drop into a panel specified around 3VA2110-7HK42-0AA0?","answer":"Both are 3-pole 100 A SENTRON 3VA2 breakers with the same frame dimensions (105 mm wide, 181 mm tall, 86 mm deep), so mechanical fit is identical. The difference is in the trip unit — 3VA2110-6HL32-0AA0 uses an ETU320 electronic release, while the 7HK42 variant carries a different release code. Check the trip curve and protection settings on your panel schedule before swapping; the wiring and bus connections are the same."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HL32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HL32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}