{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HL32-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HL32-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HL32-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HL32-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HL32-0BA0, 3-pole molded case circuit breaker, 100 A continuous rating, 242 kA interrupting at 240 V, undervoltage release.","salesMarkdown":"## What it is and what it does The Siemens SENTRON 3VA2110-6HL32-0BA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection. It carries a continuous current of 100 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel thermal budgeting. The interrupting ratings are the headline: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That 242 kA figure at 240 V means this breaker can safely clear a fault on a high-capacity transformer secondary without upstream fuses needing to coordinate — it's sized for high-available-fault-current industrial services. ## What the ratings mean for fit The 100 A continuous rating is flat from 40 °C to 70 °C — that's a wide thermal window. Many MCCBs start derating above 40 °C; this one holds its full ampacity, so it can sit in a warm enclosure next to other heat sources without upsizing the frame. The 242 kA interrupting capacity at 240 V is the highest figure in the range; it qualifies the breaker for service entrance or main feeder duty where fault current is high. The 800 V rated insulation voltage (Ui) means the breaker's internal clearances and creepage are designed for 690 V systems, which is the typical upper bound for industrial low-voltage networks. ## Integration notes The breaker measures 105 mm wide, 181 mm high, and 86 mm deep. It mounts on a DIN rail or directly to a backplate via the standard 3VA mounting footprint. The 3-pole design with undervoltage release (UVR) means it will trip on loss of control voltage — useful for emergency-stop circuits or undervoltage protection schemes. No communication function is built in; this is a plain electromechanical MCCB, not a power-metering or trip-unit-communicating variant. The supplied basic switch is order code 3VA21106HL320AA0.","metaTitle":"Siemens 3VA2110-6HL32-0BA0 SENTRON MCCB, 100 A, 242 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-6HL32-0BA0 molded case circuit breaker, 3-pole, 100 A continuous, 242 kA interrupting at 240 V. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21106HL320AA0","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB11","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=402023&mlfb=3VA2110-6HL32-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HL32-0BA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of 3VA2110-6HL32-0BA0?","answer":"Continuous current 100 A (no derating up to 70 °C), interrupting capacity 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, 3.7 kA at 690 V, 3 poles, undervoltage release, 800 V rated insulation voltage."},{"question":"Where can I buy 3VA2110-6HL32-0BA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the physical size of 3VA2110-6HL32-0BA0?","answer":"Width 105 mm, height 181 mm, depth 86 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HL32-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HL32-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}