{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HL32-0CA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HL32-0CA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HL32-0CA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HL32-0CA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HL32-0CA0, molded case circuit breaker, 3-pole, 100 A, line protection, undervoltage release, breaking capacity 242 kA at 240 V.","salesMarkdown":"The 3VA2110-6HL32-0CA0: The interrupting rating is what sets this MCCB apart for high-fault installations: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That 242 kA figure at 240 V gives you headroom for transformer-secondaries or large motor-control centers where fault current can spike. At 690 V the rating drops to 3.7 kA — still adequate for most 690 V industrial loads, but worth checking against your available fault current if you're feeding a 690 V bus. ## Undervoltage release and panel fit The UVR is factory-installed; no field retrofit required. ## Thermal performance across temperature That's unusual; many MCCBs start derating above 40 °C. Maximum power loss is 12.5 W, which is modest for a 100 A frame.","metaTitle":"Siemens 3VA2110-6HL32-0CA0 SENTRON MCCB, 100 A, 3-Pole, UVR","metaDescription":"Siemens SENTRON 3VA2110-6HL32-0CA0 molded case circuit breaker. 100 A continuous, 3-pole, line protection. Breaking capacity 242 kA at 240 V. Undervoltage release. Current producti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21106HL320AA0","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=418450&mlfb=3VA2110-6HL32-0CA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HL32-0CA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at 240 V?","answer":"242 kA at 240 V, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V."},{"question":"How do I get pricing and availability for 3VA2110-6HL32-0CA0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What are the physical dimensions of this breaker?","answer":"105 mm wide × 181 mm high × 86 mm deep (4.13 in × 7.13 in × 3.39 in)."},{"question":"Does this breaker include an undervoltage release?","answer":"Yes, it ships with a factory-installed undervoltage release (UVR) as the auxiliary release."},{"question":"What compliance documentation is available for this part?","answer":"The SENTRON series carries standard RoHS, REACH, UL, and IEC compliance documentation from Siemens."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HL32-0CA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HL32-0CA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}