{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HM46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HM46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HM46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HM46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HM46-0AA0, molded case circuit breaker, 4-pole, 100 A, line protection, ETU330 electronic trip unit, 242 kA at 240 V.","salesMarkdown":"The interrupting capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V — that last figure drops sharply because the arc energy at 690 V is harder to extinguish, so this breaker is sized for 400 V-class distribution, not 690 V motor circuits. ## Thermal performance and panel fit That 86 mm depth is compact for a 4-pole MCCB at this interrupting level; it leaves clearance behind a standard 200 mm deep gland plate.","metaTitle":"Siemens 3VA2110-6HM46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 242","metaDescription":"Siemens SENTRON 3VA2110-6HM46-0AA0 molded case circuit breaker, 100 A, 4-pole, line protection with ETU330 release. Rated 242 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Summation current formation L + N conductor","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU330","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 50%; 100%","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / lg max.":"100 A","Adjustable response value current / lg min.":"20 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=217244&mlfb=3VA2110-6HM46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HM46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-6HM46-0AA0?","answer":"Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels — no stock figures or lead-time numbers are published here."},{"question":"When sourcing 3VA2110-6HM46-0AA0, what's the closest functional second-source — 3VA1110-5EE36-0AA0?","answer":"The 3VA1110-5EE36-0AA0 is a different variant in the same SENTRON family. It is a 3-pole breaker with a different trip unit and interrupting rating. It will not drop into a 4-pole panel without rewiring the neutral conductor. For a 4-pole 100 A line protection role, the 3VA2110-6HM46-0AA0 is the correct fit."},{"question":"What is 3VA2110-6HM46-0AA0's listed depth (86 mm) on this component line?","answer":"The depth is 86 mm (3.39 in). That is the body depth excluding any protruding handle or terminals."},{"question":"What is 3VA2110-6HM46-0AA0's listed width (140 mm) on this component line?","answer":"The width is 140 mm (5.51 in). That is the case width for the 4-pole version."},{"question":"What compliance documentation does this brand provide for 3VA2110-6HM46-0AA0 (RoHS, REACH, UL, IEC)?","answer":"The SENTRON series is designed to meet IEC 60947-2 and UL 489 standards. RoHS and REACH declarations are available from Siemens on request. The front IP40 rating is stated on the nameplate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HM46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HM46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}