{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN32-0BH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN32-0BH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN32-0BH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN32-0BH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HN32-0BH0, molded case circuit breaker, 3-pole, 100 A rated continuous current, 242 kA interrupting at 240 V, line protection, ETU350 release, undervoltage release, 2 aux + 1 trip alarm HQ.","salesMarkdown":"The Siemens SENTRON 3VA2110-6HN32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current at up to 50 °C ambient, with the ETU350 electronic trip unit handling line protection. That 100 A holds flat from 40 °C through 50 °C — no early derating — then steps down to 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C. The interrupting ratings are substantial: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 5 kA at 690 V. The 3VA2110-6HN32-0BH0 measures 105 mm wide, 181 mm tall, and 86 mm deep — that 86 mm depth is the dimension that matters when you're laying out the gland plate or checking clearance behind a swing-panel door. The 12.5 W maximum power loss is the heat it dumps into the enclosure at full load — that's the number the thermal engineer uses to size the cabinet ventilation or cooling. The latching endurance of 20 000 operations means the mechanical mechanism is rated for that many close-open cycles before wear-out; for a main breaker that cycles once a day, that's about 55 years of service life.","metaTitle":"Siemens 3VA2110-6HN32-0BH0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2110-6HN32-0BH0 molded case circuit breaker, 100 A rated continuous current, 3-pole, 242 kA interrupting at 240 V. Current production. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"12.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-6HN32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"1 200 A","Adjustable response value current / lr min.":"40 A","Adjustable response value current / Isd max.":"1 000 A","Adjustable response value current / Isd min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=248710&mlfb=3VA2110-6HN32-0BH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN32-0BH0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-6HN32-0BH0?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and availability are confirmed at quote time."},{"question":"What are the key interrupting ratings for 3VA2110-6HN32-0BH0?","answer":"242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 5 kA at 690 V. The 242 kA at 240 V is the highest rating and governs high-fault panels."},{"question":"What is the depth of 3VA2110-6HN32-0BH0?","answer":"86 mm. That's the dimension from the mounting surface to the front of the breaker — the one that matters for gland-plate clearance and swing-panel door fit."},{"question":"What auxiliary contacts are included on 3VA2110-6HN32-0BH0?","answer":"2 auxiliary switches plus 1 trip alarm switch, HQ type. Factory-integrated, no separate side-mount module needed for status feedback."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN32-0BH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN32-0BH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}