{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HN32-0DL0, molded case circuit breaker, 3-pole, 100 A at 40 °C, 242 kA at 240 V, line protection with undervoltage release.","salesMarkdown":"It's a 3-pole unit rated for 100 A continuous at 40 °C, with no derating through 70 °C, so it holds its full ampacity across typical panel ambient temperatures. The interrupting ratings are substantial: 242 kA at 240 V and 187 kA at 415 V, which puts it in the high-fault-current class for industrial switchboards where available short-circuit current is high. The 100 A continuous rating is flat from 40 °C to 70 °C — no thermal derating curve to calculate, which simplifies panel sizing in warm environments. At 690 V the rating drops to 3.7 kA, so if your system voltage is higher than 500 V, confirm the available fault current stays under that limit. This is common for emergency-stop circuits or machinery that must shut down on power loss. The supplied basic switch carries order code 3VA21106HN320AA0, and the auxiliary switch configuration is 2 auxiliary switches plus 1 trip alarm switch plus 1 electrical alarm switch HQ, giving you status feedback for remote monitoring or PLC inputs. The MCCB measures 105 mm wide, 181 mm high, and 86 mm deep. Mounting is via the four-bolt pattern typical of SENTRON 3VA frames; no DIN-rail clip on this class of breaker.","metaTitle":"Siemens 3VA2110-6HN32-0DL0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2110-6HN32-0DL0 molded case circuit breaker, 100 A continuous, 3-pole, 242 kA at 240 V. Line protection with undervoltage release. Current lifecycle stage. Quote","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21106HN320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=178367&mlfb=3VA2110-6HN32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA2110-6HN32-0DL0?","answer":"242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V."},{"question":"What is the continuous current rating and does it derate with temperature?","answer":"Rated 100 A continuous from 40 °C through 70 °C — no derating required across that range."},{"question":"Where can I buy 3VA2110-6HN32-0DL0?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What auxiliary switches and releases does this breaker include?","answer":"It includes an undervoltage release (UVR) and an auxiliary switch configuration of 2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}