{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN32-0JL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN32-0JL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN32-0JL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN32-0JL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HN32-0JL0, molded case circuit breaker, 100 A, 3-pole, 242 kA at 240 V, line protection, shunt trip release.","salesMarkdown":"The Siemens SENTRON 3VA2110-6HN32-0JL0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, designed for line protection in distribution panels. It carries a shunt trip release (STL) and a full auxiliary switch set: two auxiliary switches, one trip alarm switch, and one electrical alarm switch HQ. The interrupting capacity is 242 kA at 240 VAC, 187 kA at 415 VAC and 440 VAC, 121 kA at 500 VAC, and 3.7 kA at 690 VAC. Rated current holds flat at 100 A across the full ambient range from 40 °C to 70 °C — no derating needed in a warm panel. Dimensions: 181 mm high, 105 mm wide, 86 mm deep.","metaTitle":"Siemens 3VA2110-6HN32-0JL0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2110-6HN32-0JL0 molded case circuit breaker, 100 A continuous, 3-pole, 242 kA breaking at 240 VAC. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21106HN320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=96195&mlfb=3VA2110-6HN32-0JL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN32-0JL0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at 240 V?","answer":"242 kA at 240 VAC. At 415 V and 440 V it is 187 kA, at 500 V it is 121 kA, and at 690 V it is 3.7 kA."},{"question":"What auxiliary switches and releases does this breaker include?","answer":"It includes a shunt trip release (STL), two auxiliary switches, one trip alarm switch, and one electrical alarm switch HQ."},{"question":"Where can I buy 3VA2110-6HN32-0JL0 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."},{"question":"What compliance documentation is available for this MCCB?","answer":"As a Siemens SENTRON product, it is designed to meet applicable IEC and UL standards for molded case circuit breakers. Specific RoHS, REACH, UL, and IEC declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN32-0JL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN32-0JL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}