{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HN36-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU350 electronic trip unit, 242 kA at 240 V, 187 kA at 415 V, IP40 front, current production.","salesMarkdown":"At 240 V this MCCB interrupts 242 kA — a figure that covers most utility transformer secondary faults without cascading upstream. At 415 V it still holds 187 kA, and at 690 V it drops to 3.7 kA, which is typical for a 100 A frame on a 690 V line. The high interrupting ratings at common low-voltage levels mean you can place this breaker close to the source in a high-fault-current panel and still maintain full selectivity with downstream 18 kA or 25 kA branch devices. That 105 mm width fits a standard 3-pole MCCB cutout in a distribution panelboard or switchboard. An optional motor drive is available for remote switching — the frame is prepared for it.","metaTitle":"Siemens 3VA2110-6HN36-0AA0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2110-6HN36-0AA0 molded case circuit breaker, 100 A, 3-pole, ETU350 trip unit. 242 kA at 240 V, 187 kA at 415 V. IP40 front. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"1 200 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=94421&mlfb=3VA2110-6HN36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-6HN36-0AA0?","answer":"We source and quote this part against an RFQ through independent distribution. Submit a request for the current price and lead time — both are confirmed at quote time."},{"question":"Will 3VA2110-6HN36-0AA0 drop into a panel specified around 3VA1010-2ED32-0JA0?","answer":"Both are 3-pole SENTRON MCCBs on the same frame size, so the mounting cutout and bus-bar spacing are identical. The wiring terminals and lug sizes are the same. No rewiring is needed for the panel footprint."},{"question":"What compliance documentation does Siemens provide for 3VA2110-6HN36-0AA0?","answer":"Siemens provides RoHS, REACH, and UL/IEC declarations for this MCCB as part of the standard documentation package. The reference code per IEC 81346-2 is Q."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}