{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN36-0AG0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN36-0AG0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0AG0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0AG0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HN36-0AG0, molded case circuit breaker, 3-pole, 100 A continuous rating, 242 kA interrupting at 240 V, line protection design.","salesMarkdown":"The Siemens SENTRON 3VA2110-6HN36-0AG0 is a 3-pole molded case circuit breaker rated for 100 A continuous current, built for line protection in distribution panels. The 100 A rating holds flat from 40 °C up to 70 °C ambient — no derating curve to chase across the panel temperature gradient. That simplifies BOM math when the breaker lives next to a drive or transformer that pushes enclosure temps. Rated insulation voltage is 800 V, so it's comfortable on 480 V and 600 V class systems with margin. Interrupting capacity steps down as voltage climbs: 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The 690 V number looks low, but that's typical for a 100 A frame at that voltage — if your system runs 690 V and fault current exceeds 3.7 kA, you need a larger frame or a current-limiting upstream device. Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — fits a standard MCCB footprint on DIN rail or panel-mount. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C.","metaTitle":"Siemens 3VA2110-6HN36-0AG0 SENTRON MCCB, 100 A, 3-Pole","metaDescription":"Siemens SENTRON 3VA2110-6HN36-0AG0 molded case circuit breaker, 100 A continuous, 3-pole, 242 kA at 240 V. Line protection design with auxiliary switch. Current lifecycle stage, av","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21106HN360AA0","Design Of The Auxiliary Switch":"1 auxiliary switch + 1 trip alarm switch HP","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB11","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=402791&mlfb=3VA2110-6HN36-0AG0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0AG0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-6HN36-0AG0?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the interrupting capacity at 240 V?","answer":"242 kA at 240 V. That's the highest rating in the voltage table — sufficient for most service-entrance applications with high available fault current."},{"question":"Will 3VA2110-6HN36-0AG0 drop into a panel specified for 3VA1110-5EF32-0AM0?","answer":"Both are 3-pole 100 A MCCBs in the SENTRON family, so the basic electrical fit is similar. But the 3VA2110-6HN36-0AG0 is a line-protection design with an auxiliary switch and trip alarm, while the 3VA1110 variants may differ in accessory configuration and interrupting ratings. Verify the auxiliary contact wiring and the interrupting capacity match your panel's SCCR before swapping."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"Siemens SENTRON breakers typically carry UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications. RoHS and REACH declarations are available through the Siemens support portal. Specific documentation for this order code can be requested at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0AG0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN36-0AG0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}