{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN36-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN36-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6HN36-0DA0, molded case circuit breaker, 3-pole, 100 A continuous, 242 kA interrupting at 240 V, line protection, undervoltage release.","salesMarkdown":"## MCCB for high-fault substations and feeder protection The Siemens SENTRON 3VA2110-6HN36-0DA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the entire 40 °C to 70 °C ambient range — no derating needed up to that ceiling. The 800 V rated insulation voltage suits it for 690 V line-to-line systems, though at 690 V the breaking capacity drops to 3.7 kA — that's the limit to watch if you're using it on a 690 V bus. No trip indicator on the front means fault diagnosis relies on the external UVR status or downstream annunciation. ## Panel fit and mechanical integration The 86 mm depth leaves clearance for rear-connected busbars or cable ladders in a typical 600 mm deep enclosure. No communication module means no extra wiring beyond the power terminals and the UVR coil connections.","metaTitle":"Siemens 3VA2110-6HN36-0DA0 SENTRON MCCB, 100 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2110-6HN36-0DA0 molded case circuit breaker, 100 A continuous, 3-pole, 242 kA interrupting at 240 V. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"1 200 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21106HN360AA0","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=35103&mlfb=3VA2110-6HN36-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0DA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA2110-6HN36-0DA0 at 240 V?","answer":"242 kA at 240 V. At 415 V and 440 V it's 187 kA, at 500 V it's 121 kA, and at 690 V it drops to 3.7 kA."},{"question":"Does 3VA2110-6HN36-0DA0 have a trip indicator or communication?","answer":"No trip indicator and no communication function. It does include an undervoltage release (UVR) as standard."},{"question":"Where can I buy 3VA2110-6HN36-0DA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN36-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}