{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6HN36-0FC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6HN36-0FC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0FC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0FC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2110-6HN36-0FC0, 3-pole, 100 A, 242 kA at 240 V, ETU350 trip unit, line protection version.","salesMarkdown":"## Siemens SENTRON 3VA2110-6HN36-0FC0 — 100 A MCCB with ETU350 The Siemens SENTRON 3VA2110-6HN36-0FC0 is a 3-pole molded case circuit breaker rated for a continuous current of 100 A at 40 °C through 50 °C, with a rated insulation voltage of 800 V. It carries a breaking capacity of 242 kA at 240 V and 187 kA at 415 V, dropping to 3.75 kA at 690 V — the high short-circuit ratings at the lower voltages make it a strong candidate for main feeder or high-fault-point distribution in 240 V and 415 V networks where SCCR headroom is needed. The ETU350 electronic trip unit handles the overcurrent protection logic. This is the line protection version (no ground-fault or phase-failure detection built in), so it is sized for straightforward cable and busbar protection rather than motor or generator circuits. The auxiliary contact configuration is two HQ auxiliary switches, and an integrated undervoltage release with leading NO contacts — part number 3VA9908-0BC24 — is fitted as the supplied auxiliary trip. Above that, the breaker derates linearly: 96.25 A at 55 °C, 92.5 A at 60 °C, 88.75 A at 65 °C, and 85 A at 70 °C.","metaTitle":"Siemens SENTRON 3VA2110-6HN36-0FC0 MCCB, 100 A, 242 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-6HN36-0FC0 molded case circuit breaker, 3-pole, 100 A rated current, 242 kA breaking capacity at 240 V. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"107 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 690 V":"3.75 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96.25 A","at 60 °C":"92.5 A","at 65 °C":"88.75 A","at 70 °C":"85 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2110-6HN36-0AA0","Design of the auxiliary release":"Undervoltage release with leading NO contacts (UVR(LNO))","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9908-0BC24","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"Yes","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"1 A","Adjustable response value current / li min.":"12 A","Adjustable response value current / lr min.":"0.4 A","Adjustable response value current / Isd max.":"10 A","Adjustable response value current / Isd min.":"1.5 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=436221&mlfb=3VA2110-6HN36-0FC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6HN36-0FC0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2110-6HN36-0FC0 at 415 V?","answer":"The breaking capacity is 187 kA at 415 V. At 240 V it is 242 kA, and at 690 V it is 3.75 kA."},{"question":"What trip unit does the 3VA2110-6HN36-0FC0 use?","answer":"It uses the ETU350 electronic overcurrent release. This is the line protection version with no ground-fault monitoring or phase-failure detection."},{"question":"Where can I buy 3VA2110-6HN36-0FC0 and how is it quoted?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6HN36-0FC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6HN36-0FC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}