{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6JP32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6JP32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6JP32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6JP32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-6JP32-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU550 electronic trip unit, 242 kA at 240 V, line protection, with communication.","salesMarkdown":"The Siemens SENTRON 3VA2110-6JP32-0AA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current with no derating across the full 40 °C to 70 °C ambient range — meaning it holds its full 100 A rating even in a warm panel without needing to downsize the conductor or the breaker. Its interrupting capacity reaches 242 kA at 240 V and 187 kA at 415 V, so it can be applied on high-fault utility services or transformer secondaries where a standard 65 kA MCCB would not hold. Built-in communication capability (the order code suffix signals this) allows the breaker to report status and trip events over the plant network without an add-on module. At 105 mm wide, 181 mm tall, and 86 mm deep, this breaker occupies the standard 3VA frame footprint — it drops into the same mounting cutout and bus-bar pattern as other 3VA2110 variants, so a panel laid out for a 100 A SENTRON frame accepts this unit without re-drilling or re-bussing. ## What is not built in This variant does not include a trip indicator, undervoltage release, voltage trigger, or ground-fault monitoring — those functions would require a different order-code suffix or an add-on accessory.","metaTitle":"Siemens 3VA2110-6JP32-0AA0 SENTRON MCCB, 100 A, 242 kA at 24","metaDescription":"Siemens SENTRON 3VA2110-6JP32-0AA0 molded case circuit breaker, 100 A continuous, 3-pole, ETU550 release, 242 kA at 240 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=51000&mlfb=3VA2110-6JP32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6JP32-0AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6JP32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6JP32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}