{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-6KP32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-6KP32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-6KP32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6KP32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2110-6KP32-0AA0, 3-pole, 100 A, ETU850 electronic trip unit, 242 kA at 240 V, line protection design.","salesMarkdown":"The Siemens 3VA2110-6KP32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current, with a 3-pole configuration and an ETU850 electronic trip unit. Its breaking capacity is 242 kA at 240 V and 187 kA at 415 V and 440 V — figures that govern fault-clearing capability in low-voltage distribution. The 100 A rating holds flat across the full ambient range from 40 °C to 70 °C (–), so no derating curve to calculate for typical enclosure temperatures. The 3VA2110-6KP32-0AA0 measures 86 mm deep, 105 mm wide, and 181 mm high (–). The 105 mm width is standard for a 3-pole frame in this class — expect it to occupy three 35 mm module spaces on a DIN rail. No undervoltage release or shunt trip is factory-installed, so add an external module if those functions are needed for emergency stop or undervoltage protection schemes. ## Coordination and selectivity notes The ETU850 electronic trip unit supports adjustable I²t curves and short-time delay settings, which are essential for selective coordination downstream of a larger feeder breaker. The 800 V rated insulation voltage allows use in 480/277 V and 600 V systems with margin. The communication function enables integration with energy management systems via optional PROFIBUS or PROFINET modules — the base breaker is ready for it.","metaTitle":"Siemens 3VA2110-6KP32-0AA0 SENTRON MCCB, 100 A, 242 kA at 24","metaDescription":"Siemens 3VA2110-6KP32-0AA0 SENTRON molded case circuit breaker, 3-pole, 100 A continuous, ETU850 trip unit, 242 kA breaking at 240 V. Current lifecycle. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=469015&mlfb=3VA2110-6KP32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-6KP32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-6KP32-0AA0 and get a price?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."},{"question":"What are the key ratings for 3VA2110-6KP32-0AA0?","answer":"Continuous current: 100 A (flat from 40 °C to 70 °C). Breaking capacity: 242 kA at 240 V, 187 kA at 415 V, 187 kA at 440 V, 121 kA at 500 V, 3.7 kA at 690 V. Trip unit: ETU850 electronic. Poles: 3. Insulation voltage: 800 V."},{"question":"What is the physical size of this MCCB?","answer":"Depth 86 mm, width 105 mm, height 181 mm. Fits a standard 3-pole DIN-rail footprint."},{"question":"Does this breaker have a trip indicator or undervoltage release?","answer":"No trip indicator and no undervoltage release. No voltage trigger. These functions require external add-on modules."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-6KP32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-6KP32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}