{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7HK36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7HK36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7HK36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7HK36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2, Molded case circuit breaker, 3-pole, 100 A, ETU340 electronic trip unit, 330 kA at 240 V AC.","salesMarkdown":"That's a solid advantage for anyone packing breakers into a crowded enclosure where ambient temps climb. Panel integration: it's 105 mm wide, 181 mm tall, and 86 mm deep — that's 4.1 by 7.1 by 3.4 inches.","metaTitle":"Siemens 3VA2110-7HK36-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3","metaDescription":"Siemens 3VA2110-7HK36-0AA0 SENTRON molded case circuit breaker, 100 A rated continuous current, 3-pole, ETU340 electronic trip unit. 330 kA at 240 V. Sourced to order against an RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"53 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [in]":"3.4 in","Width [in]":"4.1 in","Height [in]":"7.1 in","Number of poles":"3","Product version":"Line protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Without","Design of the overcurrent release":"ETU340","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1500","Adjustable response value time / tr min.":"1500","Product extension / optional / motor drive":"Yes","Adjustable response value current / lg min.":"100 A","Adjustable response value current / li max.":"1 500 A","Adjustable response value current / li min.":"1 500 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protection Function Of The Overcurrent Release":"ELISA LI","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Mechanical service life (switching cycles) / typical":"20 000","Type of electrical connection / for main current circuit":"double-sided box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=568758&mlfb=3VA2110-7HK36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7HK36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Is 3VA2110-7HK36-0AA0 available via RFQ confirmation and available to order?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 3VA2110-7HK36-0AA0 at different voltages?","answer":"At 240 V it's rated for 330 kA, at 415 V and 440 V it's 242 kA, at 500 V it's 187 kA, and at 690 V it's 53 kA. That covers everything from low-voltage distribution down to heavy industrial feeders."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7HK36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7HK36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}