{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7HL36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7HL36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7HL36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7HL36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-7HL36-0AA0, molded case circuit breaker, line protection, 3-pole, 100 A, ETU320 electronic trip unit, breaking capacity 330 kA at 240 V AC.","salesMarkdown":"The Siemens SENTRON 3VA2110-7HL36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 100 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That 100 A is the assigned permanent current Iu, so it handles the full load without a temperature haircut in a warm panel. The breaking capacity is substantial: 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — so it clears high-fault currents on the secondary side of a large transformer or in a heavy industrial distribution board without cascading upstream. ## Panel fit and protection The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard SENTRON 3VA frame size that drops into the same panel footprint as other 3VA2110 variants.","metaTitle":"Siemens 3VA2110-7HL36-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3","metaDescription":"Siemens SENTRON 3VA2110-7HL36-0AA0 molded case circuit breaker. 100 A continuous, 3-pole, ETU320 electronic trip. Breaking capacity 330 kA at 240 V. IP40 front. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Switching Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6 - 120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=512509&mlfb=3VA2110-7HL36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7HL36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-7HL36-0AA0 and how is it quoted?","answer":"This MCCB is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What is the breaking capacity of 3VA2110-7HL36-0AA0 at different voltages?","answer":"At 240 V AC it breaks 330 kA; at 415 V and 440 V, 242 kA; at 500 V, 187 kA; and at 690 V, 3.7 kA. That covers most industrial distribution voltages from low to medium fault levels."},{"question":"Does 3VA2110-7HL36-0AA0 drop into a panel wired for 3VA2110-7HK42-0AA0?","answer":"Both are 3-pole SENTRON 3VA2110 frame breakers with the same 105 mm width, so the mechanical footprint and bus-bar spacing are identical. The difference is the trip unit and rating — this one is a 100 A ETU320, while the 3VA2110-7HK42-0AA0 carries a different rating and trip curve. Verify the trip settings match the downstream protection study before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7HL36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7HL36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}