{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7JP46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7JP46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7JP46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7JP46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-7JP46-0AA0, molded case circuit breaker, 4-pole, 100 A continuous, ETU550 electronic trip unit, 330 kA breaking capacity at 240 V, IP40 front, 86 mm depth.","salesMarkdown":"It is a 4-pole unit with an ETU550 electronic trip unit, meaning the trip curve is programmable — not a fixed thermal-magnetic — so you can dial in coordination with downstream breakers rather than guessing. The breaking capacity tells you where this breaker can safely interrupt a fault: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. ## Sourcing and lifecycle — no obsolescence concern here The ETU550 trip unit and communication function mean this breaker is designed for modern networked distribution panels, not a legacy design being phased out. ## Panel fit and installation The 140 mm width for a 4-pole MCCB is typical for the SENTRON platform; busbar and lug kits are shared across the family. The breaker includes communication capability, so expect a plug-in module slot for PROFIBUS or PROFINET if you need remote monitoring and trip indication.","metaTitle":"Siemens 3VA2110-7JP46-0AA0 SENTRON MCCB, 100 A, ETU550, 330","metaDescription":"Siemens 3VA2110-7JP46-0AA0 SENTRON molded case circuit breaker, 100 A continuous, ETU550 electronic trip, 330 kA at 240 V, 4-pole, IP40 front. Active production. Available to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","Maximum":"1 200 A","Minimum":"150 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=215977&mlfb=3VA2110-7JP46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7JP46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2110-7JP46-0AA0 at 415 V?","answer":"242 kA at 415 V. That is the same rating as at 440 V, so it handles the most common industrial fault levels on 400 V class systems without issue."},{"question":"Will 3VA2110-7JP46-0AA0 drop into a panel specified for 5SQ2670-2YA06 without rewiring?","answer":"No — the 5SQ2670-2YA06 is a different Siemens series with a different footprint and terminal arrangement. The 3VA series uses a different mounting pattern and busbar system. You will need to verify the panel cutout and busbar adapter compatibility before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7JP46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7JP46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}