{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7MN36-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7MN36-0AB0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7MN36-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MN36-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON molded case circuit breaker, 3VA2110-7MN36-0AB0, 3-pole, 100 A, motor protection design, 330 kA breaking capacity at 240 V.","salesMarkdown":"## SENTRON 3VA2110-7MN36-0AB0 — 100 A Motor Protection MCCB The Siemens SENTRON 3VA2110-7MN36-0AB0 is a 3-pole molded case circuit breaker rated for 100 A continuous current across the full ambient range of 40 °C to 70 °C — no derating needed up to 70 °C. Designed specifically for motor protection, it includes phase failure detection and comes with two built-in auxiliary switches (HP type). The interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V, and still holds 187 kA at 500 V, dropping to 3.7 kA at 690 V. This is a current-lifecycle part, actively specified into new panels and available to order against an RFQ. That simplifies panel sizing in warm enclosures or near motor starters. At 690 V the capacity drops to 3.7 kA — still adequate for most 690 V motor circuits, but verify your available fault current if feeding a large drive bank. The motor protection design means the trip curve is shaped for overload protection of induction motors — inrush during start won't nuisance-trip, but sustained overloads above the 100 A continuous rating will clear. No undervoltage release or shunt trip is included on this variant. The supplied basic switch (order code 3VA21107MN360AA0) is the internal switching mechanism; the two HP auxiliary switches are factory-fitted and wired to the terminal block for remote status indication. No communication function is included on this variant, so it's a standalone thermal-magnetic protector.","metaTitle":"Siemens 3VA2110-7MN36-0AB0 SENTRON MCCB, 100 A, 3-Pole, Moto","metaDescription":"Siemens SENTRON 3VA2110-7MN36-0AB0 molded case circuit breaker, 100 A rated, 3-pole, motor protection design, 330 kA at 240 V. Current lifecycle stage, sourced to order. Request a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21107MN360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HP","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"30 000 W","operating power / at AC-3 / at 400 V":"55 000 W","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA11","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569436&mlfb=3VA2110-7MN36-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MN36-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-7MN36-0AB0 and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no minimum volume required."},{"question":"What is the breaking capacity of 3VA2110-7MN36-0AB0 at 240 V?","answer":"The interrupting capacity is 330 kA at 240 V, 242 kA at 415 V, 242 kA at 440 V, 187 kA at 500 V, and 3.7 kA at 690 V."},{"question":"Does 3VA2110-7MN36-0AB0 include phase failure protection?","answer":"Yes, phase failure detection is built into this motor protection breaker — it will trip if one phase is lost, preventing single-phasing damage to the motor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7MN36-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7MN36-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}