{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7MS32-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7MS32-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7MS32-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS32-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-7MS32-0HH0, 3-pole molded case circuit breaker, 100 A rated, adjustable thermal-magnetic trip 300-1500 A, breaking capacity 330 kA at 240 V, 242 kA at 415 V, 187 kA at 500 V.","salesMarkdown":"## Panel-builder commissioning note The Siemens SENTRON 3VA2110-7MS32-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous at 40 °C through 70 °C with no derating — that's unusual thermal stability for a 100 A frame. Adjustable thermal-magnetic trip covers 300 A to 1 500 A, so you can dial it to protect motor or feeder circuits without swapping the breaker body. Breaking capacity hits 330 kA at 240 V, 242 kA at 415 V, and 187 kA at 500 V, which puts it in the high-interrupting category for industrial distribution panels. Power loss maxes at 10 W, manageable for dense DIN-rail layouts in a 105 mm wide x 181 mm tall x 86 mm deep footprint. The 105 mm width x 181 mm height x 86 mm depth fits standard MCCB panel cutouts.","metaTitle":"Siemens 3VA2110-7MS32-0HH0 SENTRON MCCB, 100 A, 1500 A max t","metaDescription":"Siemens 3VA2110-7MS32-0HH0 SENTRON molded case circuit breaker, 100 A rated, adjustable trip 300-1500 A, 330 kA at 240 V. Current production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 500 A","Minimum":"300 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Starter protection","Communication Function":"No","Phase Failure Detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21107MS320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU310M","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"I","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569493&mlfb=3VA2110-7MS32-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS32-0HH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-7MS32-0HH0 and how do I get a price?","answer":"Sourced through independent distribution channels. Submit an RFQ for current pricing and availability confirmation at quote time."},{"question":"What is the breaking capacity of 3VA2110-7MS32-0HH0 at different voltages?","answer":"330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The steep drop at 690 V means this breaker is designed for 240-500 V industrial distribution, not 690 V motor circuits."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7MS32-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7MS32-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}