{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7MS32-0JL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7MS32-0JL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7MS32-0JL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS32-0JL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-7MS32-0JL0, molded case circuit breaker, 3-pole, 100 A continuous, adjustable thermal-magnetic trip 300-1500 A, 330 kA SCCR at 240 V, with shunt trip and auxiliary switches.","salesMarkdown":"The Siemens SENTRON 3VA2110-7MS32-0JL0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed in a warm panel. Its adjustable thermal-magnetic trip covers 300 A to 1 500 A, so you set the pickup to match the load rather than swapping hardware. The interrupting ratings climb to 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V; that kind of SCCR headroom means it can sit upstream of smaller branch breakers without worrying about cascading failure during a fault. ## Starter protection design — what that means for the panel The built-in shunt trip (STL) allows a remote trip signal from a safety relay or PLC — handy for E-stop chains or emergency-off circuits. The 3-pole block occupies roughly 4 inches of rail width; plan for the shunt trip wiring and auxiliary switch terminals on the left side when laying out the gland plate and wireway fill.","metaTitle":"Siemens SENTRON 3VA2110-7MS32-0JL0 MCCB, 100 A, 3-Pole, 300-","metaDescription":"Siemens SENTRON 3VA2110-7MS32-0JL0 molded case circuit breaker, 100 A continuous, 3-pole, adjustable trip 300-1500 A, SCCR 330 kA at 240 V. Current production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 500 A","Minimum":"300 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Starter protection","Communication Function":"No","Phase Failure Detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21107MS320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU310M","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"I","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569582&mlfb=3VA2110-7MS32-0JL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS32-0JL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2110-7MS32-0JL0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"Will 3VA2110-7MS32-0JL0 drop into a panel that was specified around 3VA2116-5HL32-0AK0?","answer":"Both are 3-pole SENTRON MCCBs with the same 105 mm width, 181 mm height, and 86 mm depth, so the footprint is identical. The main difference is the continuous current rating: this one is 100 A, while the 3VA2116 is a higher-frame model. If your panel was wired for the larger frame, the 100 A unit fits mechanically but you lose the higher ampacity — verify the load current before swapping."},{"question":"What compliance documentation does this breaker carry?","answer":"As a SENTRON product, it carries UL, CSA, and IEC certifications typical for MCCBs used in North American and European panels. Specific RoHS and REACH declarations are available from Siemens — the evidence does not list them here, so request them with your RFQ if compliance documentation is needed for your quality file."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7MS32-0JL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7MS32-0JL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}