{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7MS36-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7MS36-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7MS36-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS36-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-7MS36-0HC0, molded case circuit breaker, 3-pole, 100 A rated current, adjustable thermal-magnetic trip 300-1500 A, 330 kA breaking capacity at 240 V AC.","salesMarkdown":"## Siemens SENTRON 3VA2110-7MS36-0HC0 — MCCB for motor and feeder protection The adjustable thermal-magnetic trip unit covers 300 A to 1 500 A, giving you a wide band to set the instantaneous pickup for motor start or feeder fault coordination. Breaking capacity is the headline number here: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. No undervoltage release, no ground-fault module, no communication function — it's a straightforward thermal-magnetic MCCB with remote trip capability. Verify the depth clearance for the shunt trip wiring and auxiliary switch harness — 86 mm plus bend radius for the control wires.","metaTitle":"Siemens SENTRON 3VA2110-7MS36-0HC0 MCCB, 100 A, 3-pole, 1500","metaDescription":"Siemens SENTRON 3VA2110-7MS36-0HC0 molded case circuit breaker, 100 A rated at 40-70°C, 3-pole, 1500 A max adjustable trip, 330 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 500 A","Minimum":"300 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Starter protection","Communication Function":"No","Phase Failure Detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21107MS360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU310M","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"I","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569609&mlfb=3VA2110-7MS36-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS36-0HC0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-7MS36-0HC0?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is the breaking capacity of 3VA2110-7MS36-0HC0 at 240 V?","answer":"330 kA at 240 V AC. At 415 V and 440 V it's 242 kA, at 500 V it's 187 kA, and at 690 V it's 3.7 kA."},{"question":"What is the adjustable trip range on this MCCB?","answer":"The thermal-magnetic trip unit adjusts from 300 A minimum to 1 500 A maximum."},{"question":"What accessories are factory-installed on 3VA2110-7MS36-0HC0?","answer":"It includes a shunt trip release (STL) for remote tripping and two auxiliary switches (HQ) for status feedback. No undervoltage release or ground-fault module is fitted."},{"question":"What compliance documentation does Siemens provide for 3VA2110-7MS36-0HC0?","answer":"Standard Siemens SENTRON MCCBs carry UL, CSA, and IEC certifications. RoHS and REACH declarations are available from Siemens documentation. Specific certs should be verified against the nameplate for your shipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7MS36-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7MS36-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}