{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-7MS36-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-7MS36-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-7MS36-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS36-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-7MS36-0JH0, molded case circuit breaker, 3-pole, 100 A rated current, adjustable 300–1500 A overload range, 330 kA interrupting capacity at 240 V, starter protection design with shunt trip release.","salesMarkdown":"The adjustable overload range spans 300 A to 1500 A (–), which covers motor FLA from roughly 250 A up to 1200 A depending on the setting and application rules — a wide window that lets one frame size serve multiple motor ratings on the BOM. The interrupting capacity is the headline number that decides whether this breaker clears a fault without upstream damage: 330 kA at 240 V, 242 kA at 415 V and 440 V (–), 187 kA at 500 V, and 3.7 kA at 690 V. The steep drop to 3.7 kA at 690 V is a reminder that this is a 600 V class frame; at 690 V the breaker relies on the upstream protection for high faults. That means the breaker can signal its status to a PLC and be remotely tripped via a control voltage — standard for E-stop chains and automated restart schemes. The basic switch assembly is order code 3VA21107MS360AA0, which is the replaceable switching mechanism inside the frame. That 105 mm width is a standard 3-pole MCCB footprint for this class — it fits a 4-inch (101.6 mm) DIN-rail or panel-mount cutout with minimal adjustment. The 86 mm depth (3.39 in) means it clears a 4-inch deep enclosure with room for rear bus connections. Maximum power loss is 10 W, so inside a sealed panel the heat contribution is modest — no forced ventilation required for a single unit.","metaTitle":"Siemens 3VA2110-7MS36-0JH0 SENTRON MCCB, 100 A, 1500 A max,","metaDescription":"Siemens SENTRON 3VA2110-7MS36-0JH0 molded case circuit breaker, 3-pole, 100 A rated, 1500 A max setting, 330 kA IC at 240 V. Starter protection design with shunt trip. Active produ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 500 A","Minimum":"300 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Starter protection","Communication Function":"No","Phase Failure Detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21107MS360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU310M","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"I","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569614&mlfb=3VA2110-7MS36-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-7MS36-0JH0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA2110-7MS36-0JH0 at 415 V?","answer":"242 kA at 415 V. At 240 V it is 330 kA, at 500 V it is 187 kA, and at 690 V it is 3.7 kA."},{"question":"Where can I buy 3VA2110-7MS36-0JH0 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the rated current of 3VA2110-7MS36-0JH0 at 70 °C?","answer":"100 A, flat across the entire operating temperature range from 40 °C to 70 °C (–). No derating needed in a warm panel."},{"question":"Does 3VA2110-7MS36-0JH0 include a shunt trip?","answer":"Yes, the auxiliary release is a shunt trip (STL). It also carries 2 auxiliary switches plus 1 trip alarm switch (HQ)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-7MS36-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-7MS36-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}