{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-8HK46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-8HK46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-8HK46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-8HK46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-8HK46-0AA0, molded case circuit breaker, 4-pole, 100 A continuous, 1500 A frame, ETU340 electronic trip unit, 440 kA at 240 V.","salesMarkdown":"It's a 4-pole unit rated for 100 A continuous current across the full 40 °C to 70 °C ambient range, with a 1500 A frame that gives headroom for high-fault scenarios. This breaker delivers 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V. ## Trip unit and protection It carries an ETU340 electronic overcurrent release — that's the trip unit that handles long-time, short-time, and instantaneous protection curves. Power loss is 7.7 W maximum, which matters for enclosure heat rise calculations in a packed panel. The 140 mm width is a 4-pole footprint — it'll need four module spaces on the DIN rail or mounting plate.","metaTitle":"Siemens 3VA2110-8HK46-0AA0 MCCB, 100 A, 4-Pole, 440 kA","metaDescription":"Siemens SENTRON 3VA2110-8HK46-0AA0 molded case circuit breaker, 100 A continuous, 4-pole, 1500 A frame, ETU340 release. 440 kA at 240 V. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","Maximum":"1 500 A","Minimum":"1 500 A","at 240 V":"440 kA","at 415 V":"330 kA","at 440 V":"330 kA","at 500 V":"220 kA","at 690 V":"52.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"100 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU340","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 50%; 100%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"ELISA LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"L","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=568764&mlfb=3VA2110-8HK46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-8HK46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the 3VA2110-8HK46-0AA0?","answer":"100 A continuous current, 4-pole, 1500 A frame, ETU340 electronic trip unit, and interrupting ratings from 440 kA at 240 V down to 52.5 kA at 690 V."},{"question":"How do I get current pricing and availability for 3VA2110-8HK46-0AA0?","answer":"Submit an RFQ through this listing; the part is sourced to order via independent distribution, and availability with current pricing is confirmed at quote time."},{"question":"Will 3VA2110-8HK46-0AA0 drop into a panel specified around 5SQ2670-2YA63?","answer":"The 3VA2110-8HK46-0AA0 is a SENTRON 3VA series MCCB, while 5SQ2670-2YA63 is a different Siemens series. Footprint and mounting differ — verify the panel cutout and bus bar spacing before substituting, as the 140 mm width and 86 mm depth may not align."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"The SENTRON 3VA series carries IEC and UL certifications as standard for molded case circuit breakers. Specific RoHS and REACH declarations are available from Siemens documentation; no separate certificate is listed in this evidence set."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-8HK46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-8HK46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}