{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2110-8HL36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2110-8HL36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2110-8HL36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2110-8HL36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2110-8HL36-0AA0, molded case circuit breaker, 3-pole, 100 A, ETU320 electronic trip unit, 440 kA at 240 V, 330 kA at 415 V, 86 mm depth.","salesMarkdown":"The Siemens SENTRON 3VA2110-8HL36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 100 A continuous at ambient temperatures from 40 °C through 70 °C — no derating needed across that span, which simplifies panel thermal budgeting. The interrupting ratings climb to 440 kA at 240 V and hold at 330 kA through 415–440 V, then step down to 220 kA at 500 V and 52.5 kA at 690 V — giving the panel designer clear SCCR headroom across common industrial voltage levels. Maximum power dissipation is 7.7 W, which keeps heat rise manageable inside a closed enclosure even when the breaker is fully loaded. Front-face protection is IP40, adequate for clean indoor panel environments where tools or fingers won't contact live parts through the cover. The breaker accepts optional motor drive (: Yes), enabling remote open/close for automated load shedding or emergency stop circuits.","metaTitle":"Siemens 3VA2110-8HL36-0AA0 SENTRON MCCB, 100 A, 3-Pole, ETU3","metaDescription":"Siemens SENTRON 3VA2110-8HL36-0AA0 molded case circuit breaker, 100 A, 3-pole, ETU320 electronic trip. 440 kA at 240 V. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"440 kA","at 415 V":"330 kA","at 440 V":"330 kA","at 500 V":"220 kA","at 690 V":"52.5 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"100 A","at 60 °C":"100 A","at 65 °C":"100 A","at 70 °C":"100 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"7.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"100 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"1 200 A","Adjustable response value current / li min.":"150 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"L","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=376315&mlfb=3VA2110-8HL36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2110-8HL36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2110-8HL36-0AA0?","answer":"Submit an RFQ through this listing. The part is sourced via independent distribution; firm pricing and stock levels are confirmed at quote time."},{"question":"What is the interrupting capacity of this MCCB at 415 V?","answer":"330 kA at 415 V, matching the rating at 440 V. At 240 V it reaches 440 kA; at 690 V it is 52.5 kA."},{"question":"What trip unit does the 3VA2110-8HL36-0AA0 carry?","answer":"An ETU320 electronic trip unit, which supports adjustable overload and short-circuit protection settings for coordination studies."},{"question":"Does this breaker require derating at elevated ambient temperatures?","answer":"No — the 100 A rating holds from 40 °C through 70 °C without derating, simplifying thermal design in warm enclosures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2110-8HL36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2110-8HL36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}