{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-0HL36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-0HL36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-0HL36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-0HL36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON series, Molded case circuit breaker, 3VA2116-0HL36-0AA0, 3-pole, 160 A continuous, 440 kA at 415 V, ETU320 release, line protection.","salesMarkdown":"The Siemens SENTRON 3VA2116-0HL36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current, designed for line protection in industrial power distribution panels. It carries a massive 440 kA breaking capacity at 415 V AC and 187 kA at 690 V AC — that means it can safely interrupt a fault current up to that level without the arc escaping or the case rupturing, which is critical for high-fault installations like transformer secondaries or large motor control centers. The ETU320 electronic trip unit handles the overcurrent release, giving you adjustable long-time, short-time, and instantaneous protection curves — not just a fixed thermal-magnetic bimetal. ## Fit and panel integration Footprint is 105 mm wide, 181 mm tall, 86 mm deep — standard for a 160 A frame MCCB, so it drops into most existing panel layouts without re-drilling the mounting plate. If you're freezing a BOM for a new line, this part is a safe bet; no PCN or LTB watch needed today.","metaTitle":"Siemens SENTRON 3VA2116-0HL36-0AA0 MCCB, 160 A, 440 kA","metaDescription":"Siemens SENTRON 3VA2116-0HL36-0AA0 molded case circuit breaker, 3-pole, 160 A continuous, 440 kA at 415 V. ETU320 release. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2116-0HL36-0AA0","Height":"181 mm","Maximum":"0 A","Minimum":"0 A","at 415 V":"440 kA","at 690 V":"187 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU320, LI, In=160A overload protection Ir=63A... 160A short circuit protection Ii=1,5...12 x In cable connection","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$499.11","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1417412&mlfb=3VA2116-0HL36-0AA0"},"ai":{"faq":[{"question":"What trip unit does 3VA2116-0HL36-0AA0 use?","answer":"ETU320 electronic trip unit with adjustable long-time, short-time, and instantaneous protection curves."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-0HL36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-0HL36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}